set linkflap downtime
Use this command to set the time interval (in seconds) one or more ports will be held down after a
link flap violation.
Syntax
set linkflap downtime port-string downtime-value
Parameters
port‐string
downtime‐value
Defaults
None.
Mode
Switch mode, read‐write.
Example
This example shows how to set the link flap downtime on port
D2(rw)->set linkflap downtime ge.1.4 5000
clear linkflap down
Use this command to toggle link flap disabled ports to operational.
Syntax
clear linkflap down [port-string]
Parameters
port‐string
Defaults
If port‐string is not specified, all ports disabled by a link flap violation will be made operational.
Mode
Switch mode, read‐write.
Example
This example shows how to make disabled port
D2(rw)->clear linkflap down ge.1.4
Specifies the port(s) on which to set the link flap downtime.
Specifies a downtime in seconds. A value of 0 will set the downtime to
forever.
(Optional) Specifies the ports to make operational.
ge
ge
.1.4 to 5000 seconds.
.1.4 operational.
D-Series CLI Reference 4-27
set linkflap downtime