Rebuilding Logical Drives - Asus PCI-DA2100 User Manual

Pci-to-scsi ultrawide raid controller card
Hide thumbs Also See for PCI-DA2100:
Table of Contents

Advertisement

ASUS GUI RAID Manager: Array Management
4.10

Rebuilding Logical Drives

Depending on whether or not there is a spare drive, rebuilding is
initiated automatically or manually. In the presence of a spare
drive, the system automatically rebuilds onto the spare drive.
This process is done in the background, thus it appears
transparent to the user.
In the absence of a spare drive, rebuilding must be initiated
manually. Before initiating a manual rebuild, you need to first
replace the failed drive. If you install the replacement drive on
the same connector (that is, same channel and SCSI ID), then
you can proceed with the rebuilding process; otherwise, you
need to scan in the drive first.
4 4 To rebuild a logical drive
1. Display the Logical Drives window by clicking on the
Logical Drives command button or selecting the Logical
Drives command from the Open menu.
2. From the Logical Drives window, double-click the right
mouse button on the degraded logical drive. The following
menu will appear on the screen:
3. Select Rebuild.
4-24
4.10
Rebuilding Logical Drives

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pci-da2200

Table of Contents