Base Grille Water
Filtration
System
Model TlWG2L/T2RFWG2
Capacity 200 Gallons (758 Liters)
Model TlWG2/T2RFWG2
Capacity 200 Gallons (758 Liters)
System
tested and certified
by NSF International
against
NSF/ANS]
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I1"; and against
NSF/ANSl
Standard
53 for the reduction
of Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to NSF/ANSi
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSl
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
2.0182 mg/L
2.0 mg/L ± 10%
0.06 mg/L **
0.0536 mg/L
ChlorineparticulateTaste/OdOrclass
I1"
50%85%
reductionreducti°n
It3333330/n L
I At least 10,000 particles/mL I 6600 #/mL
18326 /mL
1::°13 1 ::834
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5 ***
0.010 mg/L
0.1533 mg/L
0.15 mg/L ± 10%
0.0005 mg/L
0.0005 mg/L
99.67
99.67
Lead: @ pH 8.5***
0.010 mg/L
0.1400 mg/L
0.15 mg/L ± 10%
0.0007 mg/L
0.0006 mg/L
99.50
99.57
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L ± 10%
0.0002 mg/L
0.0002 mg/L
96.54
96.54
Mercury: @ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L ± 10%
0.0005 mg/L
0.0003 mg/L
91.57
94.92
Benzene
0.005 mg/L
0.0154 mg/L
0.015 mg/L ± 10%
0.0012 mg/L
0.0006 mg/L
92.22
96.34
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L ± 10%
0.0250 m_L
0.0066 mg/L
98.58
99.63
Toxaphene
0.003 m_L
0.015 mg/L
0.015 mg/L ± 10%
0.001 mg/L
0.001 mg/L
93.33
93.33
Carbofuran
0.04 mg/L
0.0819 mg/L
0.08 mg/L _+10%
0.0400 mg/L
0.0213 mg/L
51.13
74.00
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6"F (2O°C to 22°C).
•
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement cartridge T2RFWG2, part #4396841.
In Canada, use replacement cartridge T2RFWG2, part
#4396841B. 2008 suggested retail price of $39.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model TlWG2L:
Style 1 -When
the filter indicator
reads 10%,
order a new filter. When the filter indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 -When
the filter indicator
light changes
from green to
yellow, order a new filter. When the filter indicator
light changes
from yellow to red, it is recommended
that you replace the filter.
Style
3 - When
the water
filter status
display
changes
from
"GOOD"
to "ORDER,"
order a new filter. When the filter
indicator
reads
"REPLACE,"
it is recommended
that you
replace
the filter.
Model TlWG2: Change the water filter cartridge every
6 months depending upon your usage. If the water flow to the
water dispenser or ice maker decreases noticeably before
6 months have passed, replace the water filter cartridge more
often.
•
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
•
The product is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
•
Refer to the "Assistance
or Service" section for the
Manufacturer's
name, address and telephone number.
•
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 1OO°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm
(1.9 Lpm) @ 60 psi
*Class II particle size: 1 um to <5 um
**Test requirement
is at least 100,000 particles/m L of AC Fine Test Dust.
***Compliant
for Lead reduction requirements
under NSF/ANSI Standard 53 as tested by Pace Analytical Services. Inc.
® NSF is a registered trademark
of NSF International.
15