GE 20 Owner's Manual & Installation Instructions page 12

Side by side refrigerators
Table of Contents

Advertisement

Available languages

Available languages

installation instructions
JJ-f]SHUT OFF MAiN WMER SUPPLY
[!] DRILLTHE HOLEFOR THE VALVE
Choose a location for the valve that is easily accessible.
It is best to connect into the side of a vertical water
pipe. When it is necessary to connect into a horizontal
water pipe, make tile connection to tile top or side,
rather than at the bottom,
to avoid drawing off"any sediment froln tile
water pipe.
Drill a 1/4" hole in tile water pipe (even if using a self-
piercing valve) using a sharp bit. Rclnove any burrs
resulting from drilling tile hole in tile pipe. Take care not
to allow water to drain into the drill. Failure to drill a
1/4" hole may result in reduced ice production or
smaller cubes.
i
[_] FASTENTHE SHUTOFFVALVE
Fasten the shutoff valve to tile cold water pipe with the
pipe clamp.
Tighten tile clalnp screws until tile sealing washer begins
to swell.
NOTE: Do not covertighten or you may crush tile
robing:
Washer
Pipe Clamp
Clamp Screw
--
inlet End
Vertical Cold
Water Pipe
NOTE: Commomsealth
of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal
and use is I,Ot
permitted
is'*
Massachusetts. Consult
with your licensed plumber.
[_ ROUTETHE TUBING
Route tile tubing between tile cold water line and tile
refrigerator.
Route tile tubing through a hole drilled in tile wall or
floor (behind tile refrigerator or adjacent base cabinet)
as close to tile wall as possible.
NOTE: Be sure there is sufficient extra tubing to allow
tile refrigerator to move out from tile wall after
installation.
J-if]CONNECTTHE TUBING TO THE VALVE
Place tile compression nut and ferrule (sleeve) for copper
robing onto tile end of the robing and co,mect it to the
shutoff valve.
Make sure tile tubing is fully inserted into tile valve.
Tighten tile compression mlt securel>
For plastic tubing from a GE SmartConnect
TM
Refrigerator Tubing kit, insert tile molded end
of tile tubing into tile shutoff" valve and tighten
compression nut until it is hand tight, then tighten one
additional turn with a wrench. Overtightening
may
cause leaks.
lression R ut
Packing Nut
OutJet VaJve
_
FerruJe (sJeeve)
NOTE: Commonwealth
of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal
and use is not
permitted
is'*
Massachusetts. Consult
with your licensed plumber.
[g] FLUSHOUT THE TUBING
Turn the main water supply on and flush out the tubing
until tile water is clear.
[_ CON_IECTTHE TUBING TO THE
REFRIGERATOR
NOTES:
* Before making the cosmection to the refrigerator; be
sure tile refrigerator power cord is not plugged into
the wall outlet.
If your refrigerator
does not have a water filter, we
recommend
installing
one if your water supply has
sand or particles
that could clog tile screen of tile
refrigerator's
water valve. Install it in tile water line
near tile refrigerator.
If using a GE SmartConnect
TM
Refrigerator
Tubing
kit, you
will need an additional
tube (WX08X10002)
to connect
tile filter. Do not cut plastic tube
to install filter.
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

2225

Table of Contents