Navigating Through The Modes; Manual Weld Mode; Navigate To Time Mode; Time Weld Mode - Dukane iQ Series HP User Manual

Ultrasonic hand held systems
Table of Contents

Advertisement

iQ Series,
Ultrasonic Hand Held Systems User's Manual

Navigating Through the Modes

When the generator is first powered up, the default
operating mode is Manual, and
at the top of the display as shown in Figure 5-1.

Navigate to Time Mode

1.
Follow the sequence shown in the figures to the right
to navigate from Manual mode to Time mode.
In Manual mode, press the TIME key (Figure 5-2).
2.
The phrase, Enter Changes Mode, means when the
ENTER key is pressed, the mode will change. So
press the ENTER key, and the Weld by Time screen
seen in Figure 5-3 appears.
3.
Set the time.
Use the
and the
and to set the digits for the weld time you want.
4.
Press the ENTER key to accept the time that has been
set (Figure 5-4).
Press the CANCEL key if you decide not to set the
time.
Navigating to Manual Mode
Set Time or Energy (depending on mode) to
OFF, and press ENTER.
This will put you back in Manual mode.
Alternately:
Find an empty setup. Press SETUP.
Press ENTER.
A pop-up screen about defaults appears.
Setup #1Empty
Load Defaults?
Select YES to load the default operating mode
which is Manual, and you can weld using the
Manual mode.
Page  4 
Manual Weld
+ -
keys to move the cursor
NOTE
NO
YES
is shown
Manual Weld
Weld Time 0.000 S
Weld Energy 0 J
# 2
Figure 5-1 Manual Weld Mode
Manual Weld
Weld By Time
Enter Changes Mode
Figure 5-2 Navigate to Time Mode
Weld by Time
Weld By Time
Press Enter To Accept
Press Cancel To Abort
Figure 5-3 Time Weld Mode - 1
Weld by Time
Press Enter To Accept
Press Cancel To Abort
Figure 5-4 Time Weld Mode - 2