PID parameter settings "P I d"

No.
Item Code
P -1
1
Proportional band
(PID set 1)
1 -1
2
Reset time
(PID set 1)
D -1
3
Rate time
(PID set 1)
O L -1
4
MV lower limit
(PID set 1)
O H -1
5
MV upper limit
(PID set 1)
R E -1
6
Manual reset
(PID set 1)
D R -1
7
Brake
(PID set 1)
D P -1
8
Disturbance inhibit
proportional band
(PID set 1)
D 1 -1
9
Disturbance inhibit
reset time
(PID set 1)
D D -1
10
Disturbance inhibit
rate time
(PID set 1)
P -2
11
Proportional band
(PID set 2)
1 -2
12
Reset time
(PID set 2)
D -2
13
Rate time
(PID set 2)
O L -2
14
MV lower limit
(PID set 2)
O H -2
15
MV upper limit
(PID set 2)
R E -2
16
Manual reset
(PID set 2)
B R -2
17
Brake
(PID set 2)
D P -2
18
Disturbance inhibit
proportional band
(PID set 2)
D I -2
19
Disturbance inhibit
reset time
(PID set 2)
D D -2
20
Disturbance inhibit
rate time
(PID set 2)
Item
Factory
User
Setting
Setting
100.0
0
0
0.0
100.0
50.0
0
100.0
120
0
100.0
0
0
0.0
100.0
50.0
0
100.0
120
0
Chapter 7. PARAMETER SETUP
Setting
P
: 0.0 to 999.9% (0D, 6D output models)
0.0 enables ON-OFF control.
0.1 to 999.9% (models other than 0D and 6D output
models)
I
: 0 to 3600s
0 disables integrating action.
D
: 0 to 1200s
0 disables derivative action.
O L
: -10.0 to MV upper limit %
O H
: MV lower limit to 110.0%
R E
: 0.0 to 100.0%
B R
: 0 to 30
0 disables the brake function.
D P
: 0.1 to 999.9%
D 1
: 1 to 3600s
D D
: 0 to 1200
0 disables derivative action.
[Note]
• On 0D and 6D output models, when
ON-OFF control is enabled. "– – – –" is displayed for
I
D
O L
O H
R E
items
,
,
,
,
,
setting is not possible.
• When variable parameter
position control only) on 2G output models,
"– – – –" is displayed for items
setting is not possible.
I
• When
setting is not 0, "– – – –" is displayed for
and setting is not possible.
• When variable parameter
disabled), "– – – –" is displayed for
not possible.
• When variable parameter
degrees of freedom PID disabled), the items for
D P
D 1
D D
,
,
are not displayed.
• On heat/cool models, the set No. of the PID parameter
used for the PID set No. is as follows:
PID Set No. Designated in the
Program or Zone No. According
to Automatic Selection of PID Set
1
2
3
4
P
setting is 0.0,
D P
D I
D D
,
and
, and
M . -C
setting is 2 (estimated
O L
O H
and
, and
R E
S T
setting is 0 (smart-tuning
B R
and setting is
2 P 1 D
setting is 0 (2
PID Set PID Set
(heat)
(cool)
1
2
3
4
5
6
7
8
7-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents