Fig 10: Wall Mounting - Siemens SICLOCK GPS1000 User Manual

Hide thumbs Also See for SICLOCK GPS1000:
Table of Contents

Advertisement

User Manual SICLOCK GPS1000

Fig 10: Wall mounting

(a) Mark the position of the mounting holes at the planned place with the aid of the base plate (5), drill the holes and insert
dowels.
.
(b) In preparation of the antenna installation, it shall be taken into account whether the antenna is to be assembled for wall
mounting or flat roof installation.
When installing the antenna on a flat roof, (Fig 9), the connecting cable of the antenna head (1) is inserted in a
straight line through 2 opposite openings of the cube (2), the antenna head support is then pushed into the opening
of the cube as far as possible, and tightened gently on the left and on the right with the 2 hexagonal socket set
screws provided.
Now the connecting cable is inserted from above through the antenna stand (5), the cube (2) is slipped as far as it
will go on the holding arm and tightened gently on the left and on the right with the 2 hexagonal socket set screws
provided. After radial adjustment (which is not influencing the signal reception quality) of the antenna head (loosen
the hexagonal socket set screws again) the hexagonal socket set screws are retightened.
Finally the opening in the cube (2) is closed with the sealing cover (4) and the two hexagonal socket set screws on
the left and right are tightened gently.
For wall mounting (Fig. 10), the connecting cable of the antenna head (1) is inserted through the cube (2) at a right
angle, the antenna head support is pushed into the opening of the cube as far as it will go and the two hexagonal
socket set screws on the left and right gently screwed tight.
Now the connecting cable is inserted from above through the antenna stand (5), the cube (2) is slipped as far as it
goes on the holding arm and tightened gently left and right with the 2 hexagonal socket set screws provided. Set up
the stand, loosen the hexagon socket set screws again, align the cover surface of the antenna head parallel to one
edge of the base plate and tighten the hexagon socket set screws.
Finally the remaining opening in the cube (2) is closed with the sealing cover (4) and the two hexagon socket set
screws left and right are screwed tight.
.
c) The best position of the drill hole through the wall or through the roof is underneath and in the middle of the base plate.
The connecting cable is inserted through the drill hole and the complete antenna stand screwed on.
The connecting cable can also be passed through the slot in the base plate and then outside the base plate through the wall or
roof.
Order numberr 2XV9450-1AR82-BA
1 - Antenna head
2 - Cube with 6 hexagon socket set screws
3 - Allan key for cube installation
4 - Sealing cover
5 - Antenna stand with base plate and holding arm