Should your unit fail to operate properly, check that there is power to the unit and that the hopper contains ice. If
the unit does not dispense, check the following chart under the appropriate symptoms to aid in locating thede-
fect.
Trouble

BLOWN FUSE OR CIRCUIT BREAKER

GATE DOES NOT OPEN AGITATOR DOES
NOT TURN.
GATE DOES NOT OPEN OR IS SLUGGISH.
AGITATOR TURNS.

GATE OPENS. AGITATOR DOES NOT TURN.

ICE DISPENSES CONTINUOUSLY.

SLUSHY ICE. WATER IN HOPPER.

TROUBLESHOOTING GUIDE

A.
B.
C.
A.
B.
C.
A.
B.
C.
A.
B.
C.
A.
B.
C.
A.
B.
C.
Probable Cause
Short circuit in wiring.
Defective gate solenoid.
Defective agitator motor.
No power.
Bent depressor plate (does not actuate switch).
Defective dispensing switch.
Defective gate solenoid.
Weak gate spring
Excessive pressure against gate slide.
Ice solidified in hopper.
Defective agitator motor.
Defective capacitor.
Stuck or bent depressor plate (does not release
switch).
Defective dispensing switch.
Improper switch installation.
Blocked drain.
Unit not level.
Poor ice quality due to water quality or icemaker
problems