Troubleshooting - Hitachi CML158XW User Manual

Colour lcd monitor
Hide thumbs Also See for CML158XW:
Table of Contents

Advertisement

Troubleshooting

This LCD Monitor has pre-adjusted using factory standard VGA timings. Due to the output
timing differences among various VGA cards in the market, users may initially experience
an unstable or unclear display whenever a new display mode or new VGA card is
selected.
Attention
This LCD Monitor Supports Multiple VGA Modes.
Refer to the Standard Timing Table for a listing of modes supported by this LCD Monitor.
PROBLEM
The picture is unclear and unstable, please perform the following steps :
1. Enter PC to "Shut Down Windows" status while you're in MS-Windows environment.
2. Check the screen to see if there's any black vertical stripes appear. If there are, take
advantage of the "Clock" function in OSD menu and adjust (by increment or decrement
numbers) until those bars disappear.
3. Move to "Phase" function in OSD menu again and adjust the monitor screen to its most
clear display.
4. Click "No" on "Shut Down Windows" and back to the normal PC operating environment.
PROBLEM
If there's no picture on the LCD Monitor, please perform the following steps:
1. Make sure the power indicator on the LCD Monitor is ON, all connections are secured,
and the system is running on the correct timing.
timing.
2. Turn off the LCD Monitor and then turn it back on again. If there is still no picture, press
the Adjustment Control button several times.
3. If step 2 doesn't work, connect your PC system to another external CRT.
system Functions properly with a CRT Monitor but it does not function with the LCD
Monitor, the output timing of the VGA card may be out of the LCD's synchronous range.
Please change to an alternative mode listed in the Standard Timing Table or replace
the VGA card, and then repeat steps 1 and 2.
PROBLEM
If you have chosen an output timing that is outside of the LCD Monitor's synchronous
range (Horizontal: 24 ~ 61 KHz and Vertical: 49 ~ 75 Hz), the OSD will display a "Out of
Range" message. Choose a mode that is supported by your LCD Monitor.
Also, if the signal cable is not connected to LCD monitor at all or properly, the monitor
screen will display a message "No Input Signal".
20
Picture is unclear and unstable
There is no picture on LCD Monitor
There is no picture on LCD Monitor
Refer to Chapter 3 for information on
If your PC