6.2 Communication setup

To congure the setup of the communication using NETWORK BRIDGE for
the projector, use items in the COMMUNICATION menu. Open the menu of
the projector and select the OPTION - SERVICE - COMMUNICATION menu.
(
OPTION menu – SERVICE – COMMUNICATION in the User's Manual –
Operating Guide)
1) Using the COMMUNICATION TYPE menu, select the NETWORK BRIDGE
for the CONTROL port.
2) Using the SERIAL SETTINGS menu, select the proper baud rate and parity
for the CONTROL port, according to the specication of the RS-232C port of
the connected device.
BAUD RATE
Data length
3) Using the TRANSMISSION METHOD menu, set up the proper method for the
CONTROL port according to your use.
• The OFF is selected for the COMMUNICATION TYPE as the default
NOTE
setting.
• Using the COMMUNICATION menu, set up the communication. Remember
that an unsuitable setup could cause malfunction of communication.
• When COMMUNICATION TYPE is set to NETWORK BRIDGE, the CONTROL
port doesn't accept RS-232C commands.

6.3 Communication port

For the NETWORK BRIDGE function, send the data from the computer to the
projector with using the Network Bridge Port that is congured in the "Port
Settings" of web browser. (
• Except for 9715, 9716, 9719, 9720, 5900, 5500, 4352 between 1024
NOTE
and 65535 can be set up as the Network Bridge Port number. It is set to 9717
as the default setting.
Item
4800bps/9600bps/19200bps/38400bps
PARITY
NONE/ODD/EVEN
8 bit (xed)
Start bit
1 bit (xed)
Stop bit
1 bit (xed)
50)
6. Network Bridge Function
Condition
75