SJ100 Series Supplemental Sheet (NBM585XA-12)
Note 1:
The revision level of the MFG No. distinguishes the following changes in Function Codes A81, C31
and C32 . The Inverter MGF No. is shown on the Specification Label (Nameplate), located on the right
side of the housing. The changes apply to inverters, which carry a revision code per the table below.
When you copy parameters between units manufactured before and after this change with a copy unit,
confirm Function Codes C31 and C32.
Example of MFG No. :
112H T123451J001
Revision
A...K...1A...1K...2A...2H...
Revision Increment--------
Page
OLD DEFAULT SETTING:
3-18
Func.
Code
A81
AVR function
select
NEW DEFAULT SETTING:
*Inverters manufactured after the revision as defined in Note 1 will have the following settings:
Func.
Code
A81
AVR function
select
"A" Function
Name
Automatic (output) voltage
regulation, selects from three
types of AVR functions, three
option codes:
00...AVR enabled
01...AVR disabled
02...AVR enabled except
during deceleration
"A" Function
Name
Automatic (output) voltage
regulation, selects from three
types of AVR functions, three
option codes:
00...AVR enabled
01...AVR disabled
02...AVR enabled except
during deceleration
NBM585XA-12
ATTENTION
Inverter Models
SJ100-002NFU
SJ100-004-022NFU
SJ100-037LFU
SJ100-055,075LFU
SJ100-004HFU
SJ100-007-040HFU
SJ100-055,075HFU
Changes
Description
Description
1/2
Revision
before change
2E
2G
2E
K
2F
2G
L
Run-
Defaults
time
EU/
Units
Edit
US
02
-
Defaults
Run-
time
EU/
Units
Edit
US
00
-
Applied
Revision
2H
2H
2H
M
2H
2H
M
DOP,DRW,DOP+
Func.
Name
Code
F-03
AVR
MODE
DOP,DRW,DOP+
Func.
Name
Code
F-03
AVR
MODE

Advertisement

loading

Summary of Contents for Hitachi SJ100 Series

  • Page 1 SJ100 Series Supplemental Sheet (NBM585XA-12) ATTENTION Note 1: The revision level of the MFG No. distinguishes the following changes in Function Codes A81, C31 and C32 . The Inverter MGF No. is shown on the Specification Label (Nameplate), located on the right side of the housing.
  • Page 2 Changes Page OLD DEFAULT SETTING: 3-32 “C” Function Defaults DOP,DRW,DOP+ Run- time Func. Func. Name Description Units Name Edit Code Code Reserved Factory use only; do not F-35 OUT-TM change O/C-1 Terminal 11 Select logic convention, two F-35 OUT-TM active state option codes: O/C-2 00…normally open [NO]...

This manual is also suitable for:

Sj100-002nfuSj100-004-022nfuSj100-037lfuSj100-055lfuSj100-075lfuSj100-004hfu ... Show all