Mitsubishi Electric FR-F700 Manual page 25

F700 series
Hide thumbs Also See for FR-F700:
Table of Contents

Advertisement

Function
Parameters
261
Power failure stop selection
Subtracted frequency at deceleration
262
start
263
Subtraction starting frequency
264
Power-failure deceleration time 1
265
Power-failure deceleration time 2
Power failure deceleration time
266
switchover frequency
267
Terminal 4 input selection
268
Monitor decimal digits selection
269
Parameter for manufacturer setting. Do not set.
Rotation direction detection selection at
299
restarting
331
RS-485 communication station
332
RS-485 communication speed
333
RS-485 communication stop bit length
RS-485 communication parity check
334
selection
RS-485 communication number of
335
retries
RS-485 communication check time
336
interval
RS-485 communication waiting time
337
setting
Communication operation command
338
source
339
Communication speed command source
340
Communication startup mode selection
341
RS-485 communication CR/LF selection
342
Communication EEPROM write selection
343
Communication error count
495
Remote output selection
496
Remote output data 1
497
Remote output data 2
503
Maintenance timer
504
Maintenance timer alarm output set time
549
Protocol selection
NET mode operation command source
550
selection
PU mode operation command source
551
selection
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
563
Energization time carrying-over times
564
Operating time carrying-over times
571
Holding time at a start
575
Output interruption detection time
576
Output interruption detection level
577
Output interruption release level
611
Acceleration time at a restart
*1
Differ according to capacities. (55K or less/75K or more)
Name
Setting Range
0, 1, 2
0 to 20Hz
0 to 120Hz, 9999
0 to 3600/ 360s
0 to 3600/ 360s, 9999
0 to 400Hz
0, 1, 2
0, 1, 9999
0, 1, 9999
0 to 31(0 to 247)
3, 6, 12, 24, 48, 96, 192,
384
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0, 0.1 to 999.8s, 9999
0 to 150ms, 9999
0, 1
0, 1, 2
0, 1, 2, 10, 12
0, 1, 2
0, 1
0, 1
0 to 4095
0 to 4095
0 (1 to 9998)
0 to 9998, 9999
0, 1
0, 1, 9999
1, 2
0.1 to 1.0s
0.0 to 20.0s
0 to 500/0 to 3600A
0 to 65535
0 to 65535
0.0 to 10.0s, 9999
0 to 3600s, 9999
0 to 400Hz
900 to 1100%
0 to 3600s, 9999
Increments
Initial Value
1
0.01Hz
0.01Hz
0.1/0.01s
0.1/0.01s
0.01Hz
1
1
1
1
1
1
1
1
0.1s
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0.1s
0.1s
Rated inverter
0.01/0.1A
*1
*1
1
1
0.1s
0.1s
0.01Hz
0.1%
0.1s
Refer to
page
0
43
3Hz
43
60Hz
43
5s
43
9999
43
60Hz
43
0
35
9999
32
9999
33
0
38
96
38
1
38
2
38
1
38
0s
38
9999
38
0
44
0
44
0
37
1
38
0
38
0
38
0
44
0
44
0
44
0
44
9999
44
0
38
9999
44
2
44
1s
44
0s
44
44
current
0
32
0
32
9999
29
1s
39
0Hz
39
1000%
39
5/15s
33
*1
26