Function
Parameters
Stall prevention operation reduction
66
starting frequency
67
Number of retries at alarm occurrence
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Alarm code output selection
77
Parameter write selection
78
Reverse rotation prevention selection
79
Operation mode selection
Motor capacity (simple magnetic flux
80
vector control)
90
Motor constant (R1)
100
V/F1 (first frequency)
101
V/F1 (first frequency voltage)
102
V/F2 (second frequency)
103
V/F2 (second frequency voltage)
104
V/F3 (third frequency)
105
V/F3 (third frequency voltage)
106
V/F4 (fourth frequency)
107
V/F4 (fourth frequency voltage)
108
V/F5 (fifth frequency)
109
V/F5 (fifth frequency voltage)
117
PU communication station
118
PU communication speed
119
PU communication stop bit length.
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
PU communication CR/LF presence/
124
absence selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
PID control automatic switchover
127
freqeuncy
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
*1
Differ according to capacities. (55K or less/75K or more)
*2
Setting can be made for the 75K or more.
23
Name
Setting Range
0 to 400Hz
0 to 10, 101 to 110
0 to 10s
0
0 to 10%
*2
0, 1, 2, 20
0 to 15/0 to 6, 25
0 to 7, 10 to 17
0 to 8
0 to 3, 14 to 17
0, 1, 2
0, 1, 2
0, 1, 2
0, 1, 2, 3, 4, 6, 7
0.4 to 55kW, 9999
/0 to 3600kW, 9999
0 to 50Ω, 9999
/0 to 400mΩ, 9999
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0, 0.1 to 999.8s, 9999
0 to 150ms, 9999
0, 1, 2
0 to 400Hz
0 to 400Hz
0 to 400Hz, 9999
10, 11, 20, 21, 50, 51, 60,
61
0.1 to 1000%, 9999
0.1 to 3600s, 9999
0 to 100%, 9999
0 to 100%, , 9999
0 to 100%, 9999
0.01 to 10.00s, 9999
Increments
0.01Hz
1
0.1s
1
0.1%
1
1
*1
1
1
1
1
1
1
1
0.01/0.1kW
*1
*1
0.001Ω/
0.01mΩ
*1
*1
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
1
1
1
1
1
0.1s
1
1
0.01Hz
0.01Hz
0.01Hz
1
0.1%
0.1s
0.1%
0.1%
0.01%
0.01s
Refer to
Initial Value
page
60Hz
30
0
34
1s
34
0
34
0%
31
0
34
2
35
1
35
1
36
14
36
0
36
0
36
0
36
0
37
9999
37
9999
37
9999
38
0V
38
9999
38
0V
38
9999
38
0V
38
9999
38
0V
38
9999
38
0V
38
0
38
192
38
1
38
2
38
1
38
9999
38
9999
38
1
38
60Hz
39
60Hz
39
9999
39
10
39
100%
39
1s
39
9999
39
9999
39
9999
39
9999