HP LaserJet Quick Reference Service Manual Page 45

Volume i.
Hide thumbs
Also See for LaserJet
User manual - 449 pages
Manual - 432 pages
Software manual - 418 pages
4Si, IIISi
The fuser is improperly seated.
The connector J201 is improperly connected.
– Reseat the connector J201 on the sensor PCA.
The SW 101 is disengaged.
– Check the SW101 to make sure it is engaged with the top cover
closed.
A temporary error has occurred.
– Turn the printer off. Short the DC controller CP005 to bypass the
Error 50 time delay.
IIIP, IIP Plus, IIP
The fuser assembly is defective.
A temporary error has occurred.
– Turn the printer off. Short the C212 on the DC Controller to
bypass the Error 50 time delay.
The power supply is defective.
IIID, III, IID, II
The fuser is defective.
The AC power module is defective.
A temporary error has occurred.
– Turn the printer off. LJ II only: Short the C211 on the DC
controller to bypass the Error 50 time delay. LJ IID only: Short the
C216 on the DC controller to bypass the Error 50 time delay.
EN
Error Codes – 43