Mode Control Motor
2.
Test
1 .
4 .
Disconnect the 7P connector from the mode control
motor.
Connect battery power to the No, 1 terminal, and
g r o u n d t h e N o . 7 t e r m i n a l ,
CAUTION: Never connecl the battery in iho oppo-
site direction.
U s i n g a j u m p e r w i r e , c o n n e c t t h e N o . 7 t e r m i n a l
i n d i v i d u a l l y t o t h e N o . 2 , 3 , 4 , 5 a n d 6 t e r m i n a l s i n
that order. Each time the connection is made, the
mode control motor should run smoothly and stop.
NOTE: lf the mode control motor does not run when
jumping the first terminal, jump that terminal again
after jumping the other terminals. The mode control
motor is OK if it runs when jumping the first termi-
n a l a g a i n .
MODE CONTROL MOTOR
lf the mode control motor does not run in step 3,
remove it. then check the mode control linkage and
doors for smooth movement. lf they move smoothly,
reolace the mode control motor,
Replacement
1. Disconnect the 7P connector from the mode control
motor,
Remove the rod from the arm of the mode control
motor.
Remove the tyvo self-tapping screws and the mode
control motor.
lnstall in the reverse order of removal. After installa'
t i o n , m a k e s u r e t h e m o d e c o n t r o l m o t o r r u n s
smoothly.
7P CONNECTOR