FX-980
5.1 Overview
This chapter contains information necessary for troubleshooting. Like
other chapters, this chapter does not include the information common to
the FX-2170.
5.2 Troubleshooting Information
This section gives you troubleshooting information to let you test points
for replaceable units.
5.2.1 Printhead
See the FX-2170 Service Manual.
Troubleshooting
5.2.2 Sensors
The information for this section is the same as for the FX-2170 except
for the points below:
Table 5-1. Sensor Tests Points
Sensor CN
Test Pin
Number
Number
CN12
1: Release1
(Release
2: GND
sensor 1)
CN16
1: Release 2
(Release
2: GND
sensor 2)
CN15
1: COPEN
(Case open
15: GND
sensor)
See the FX-2170 Service Manual.
Others
5.2.3 Motors
See the FX-2170 Service Manual.
Overview
Revision A
Test Method
(Set the Meter to the DC
Reading
Voltage.)
Place one lead on pin 1 and the
Open: +5
other lead on pin 2, and check
Short: 0V
the voltage while toggling the
sensor lever.
Place one lead on pin 1 and the
Open: +5
other lead on pin 2, and check
Short: 0V
the voltage while toggling the
sensor lever.
Place one lead on pin 1 and the
Open: +5
other lead on pin 15, and check
(Case Open)
the voltage while toggling the
Short: 0V
sensor lever.
(Case closed)
Meter
52