Portable logging haze meter

Advertisement

Quick Links

Instruction Manual
HI 93124
Portable Logging
Haze Meter
w w w . h a n n a i n s t . c o m
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI 93124 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hanna Instruments HI 93124

  • Page 1 Instruction Manual HI 93124 Portable Logging Haze Meter w w w . h a n n a i n s t . c o m...
  • Page 2: Table Of Contents

    Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the meter. All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained This manual will provide all necessary information for a correct use.
  • Page 3: Principle Of Operation

    PRINCIPLE OF OPERATION FUNCTIONAL DESCRIPTION HI 93124 has been designed to perform turbidity measurements according to the EBC (European Brewery Convention) Standard. The instrument functions by passing a beam of infrared light through a cuvette containing the sample being measured. The light source is a High Emission Infrared LED with a wavelength peaking at 890 nm, ensuring that the interference caused by colored samples is minimum.
  • Page 4: Specifications

    SPECIFICATIONS OPERATIONAL GUIDE The instrument is supplied complete with batteries. Before starting operations, install the batteries while paying attention to their polarity (see also “Battery Replacement” Range 0 to 10.00 EBC section). To maximize the battery life the meter automatically switches off after 5 10 to 250 EBC minutes of non-use.
  • Page 5: Sources Of Interference

    • Press the READ key and the LCD will display a blinking “SIP” (Sampling In VIEWING LOGGED DATA Progress). The measured value will appear after approximately 25 seconds. • Press ALT+VIEW keys: the last sample will be displayed. • Press the “right arrow” key to scroll among turbidity value, date and time of the sample.
  • Page 6: Calibration

    STANDARD SUSPENSION Note: In order to minimize any error introduced by the cuvette, it is recommended Hanna Instruments supplies HI 93124 with the AMCO-AEPA-1 standards which to use the same cuvette during calibration and for measurements. has a long shelf life at all concentrations (approximately six months, if free from •...
  • Page 7: Tips For Accurate Operation

    • Internal communication error (*) If any problem is experienced during measurements, please contact your dealer or the nearest Hanna Instruments Customer Service Department. • Internal Bus error (*) (*) Contact the nearest Hanna Instruments Customer Service Department.
  • Page 8: Battery Replacement

    HI 92000 Windows ® compatible application software HI 920011 5 to 9-pin RS232 connection cable Hanna Instruments reserves the right to modify the design, construction and HI 93703-50 Cleaning solution, 230 mL bottle appearance of its products without advance notice.
  • Page 9 SALES AND TECHNICAL SERVICE CONTACTS Australia: Tel. (03) 9769.0666 • Fax (03) 9769.0699 China: Tel. (10) 88570068 • Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 • Fax (07851) 9129-99 Greece: Tel. (210) 823.5192 • Fax (210) 884.0210 Indonesia: Tel.