G. High-voltage Power Supply Unit
1) Remove the right rear and rear covers.
2) Disconnect the 2 connectors.
3) Remove the screw (M4), the 2 screws
(M3), and then the high-voltage power
supply unit.
Connectors
Screws (M4)
Screws (M3)
High-voltage power supply unit
Figure 3-8-16
H. Cassette Paper-size Sensing PCB
1) Remove the cassettes.
2) Remove the power supply following
steps 1-7 on Page 3-48.
3) Disconnect the connector, remove the
screw, then take out the cassette paper-
size sensing cover.
Connector
Screw
Cassette paper-size sensing cover
Figure 3-8-17
4) Disconnect the connector and remove
the 3 screws from each PCB, then take
out the cassette-size sensing PCBs.
Connectors
Screws
Upper-cassette paper-size sensing PCB
Lower-cassette paper-size sensing PCB
Figure 3-8-18