Configuration Settings
When DIP switch A10 is turned ON while the spa is powered up and running, the system will enter the Edit
menu for configuration settings.
• Press any temperature button to scroll through the list of settings shown in the table below.
• Pres JETS 1 on the main control panel to select a feature. The configuration setting will flash.
• Press any temperature button to scroll through the various configuration settings for the feature.
• Pres JETS 1 to select a configuration and return to the feature list.
• Pres TEMP to continue scrolling through the list.
• Continue until all settings are chosen.
• Turn DIP switch A10 to the OFF (down) position.
The spa will automatically reset and begin to run with the new settings.
Do NOT start up the spa with A10 turn on or the CFE error will occur. CFE errors are illegal
configurations such as a pump blower set to run on the same output. The configuration must be corrected
before the spa will operate.
Message
Message Description
Pump 1 in filter (w/circulation
F 1
pump
24
24-hour time
t c
Celsius
t o
Timeouts
1 t
Pump 1 low timeout
L t
Light timeout
S c
Scrunch Panel
c t
Circ Type
P 1
Pump 1 Speeds
P 2
Pump 2 Speeds
P 3
Pump 3 Speeds
P 4
Pump 4 Speeds
Page 70
Settings
N
Y
Allows P1 low to operate in filter cycles to add extra
filtration
N = normal; Y = Pump 1 with Circ
N
Y
N = 12-hour (am/pm); Y = 24-hour (military)
N
Y
N = Fahrenheit; Y = Celsius
1
F
2
3
4
5
6
1-6 = 10, 20, 30, 40, 50, 60 minutes; F = 15 minutes
d
1
2
3
4
d = Use "Timeouts" value above; 1-4 = number of
hours
d
1
2
3
4
d = Use "Timeouts" value above; 1-4 = number of
hours
N
Y
N = Normal button positions on ML900; Y = Scrunch
N
A
3
P
N = Non circ; A = 24-hour; 3 = 24-hour w/3°F shutoff
outside filter; P = Acts like Pump 1 Low (filter cycles,
polls, etc.)
1
2
1 = 1 speed; 2 = 2 speed
0
1
2
0 = Disabled; 1 = 1 speed; 2 = 2 speed
0
1
2
0 = Disabled; 1 = 1 speed; 2 = 2 speed
0
1
E
0 = Disabled; 1 = 1 speed; E = On/Off via External
Relay
Two
Three
Five
pump
pump
pump
system
system
system
with
TV
N
N
N
N
N
N
F
F
2
2
4
4
N
N
P
P
N or P
2
1
2
1
2
1
0
1
2005 Spa Owner's Manual
8/1/2005
N
N
N
F
2
4
N
2
2
0
0

Hide quick links: