SETTING INSTRUCTIONS

SETTING THE CLOCK

After the recessed R/S (reset) button
has been pressed the display appears
as shown, with the colon blinking, and
all the factory pre-set conditions will
be present.
To set the clock to the correct time,
press and release the button marked
PROG. The digits blink.
Press the DAY button (the digits stop
blinking) until the correct day number
is shown. (1 = Monday).
Press and release the + or - buttons to change the time by one
minute, or press and hold down to change the time in ten minute
steps.
When the time is correct press PROG to start the clock and continue
setting sequence.
SETTING THE OSC PERIOD (IF ENABLED)
This display will only appear if the
OSC function has been enabled.
Use the + or - button to select an OSC
period. The choices are 0:30 (30
minutes), 1:00 (one hour), 1:30, and
2:00.
The recommended initial setting is 0:30, for more details see the
post-commissioning notes in the Installation & Commissioning Guide.
If the OSC period is set to 0:00, the function is disabled.
When set as required press PROG to continue.
SETTING THE EVENT TIMES &
TEMPERATURES
The installer will have configured the
TP75H to run in 7 day mode or 5/2 day
mode by means of a switch on the
back of the unit.
The first event (time and temperature)
is displayed, together with the day (7
day mode) or days (5/2 day mode)
when it is active. Note that the day
number(s) displayed will reflect the
current day.
To step through the six available events
press and release the NEXT button.
Whilst each event is on display, it may
be altered as required.
+1 HR
+2 HR
+3 HR
+1 HR
+2 HR
+3 HR
+1 HR
+2 HR
+3 HR
7 day mode
Event No.
Control temp.
+1 HR
+2 HR
+3 HR
Day
Time
5/2 day mode
Event No.
Control temp.
+1 HR
+2 HR
+3 HR
Days
Time
..../continued
Press and hold down the + or - buttons to change the event time in
ten minute steps. Press and release to change by one minute.
Press and release the
button to raise the control temperature by
0·5°C (1°F), or press and release the
temperature by 0·5°C. Press and hold down these buttons to make
larger changes to the control temperature.
In addition to being able to programme a temperature, it is also
possible to programme an OFF simply by pressing the
the symbol 'OF' appears on the display.
Caution: If Off is selected, frost protection is not provided.
When all events for the day(s) on display are as required press DAY
to show the following day's events.
The display will appear similar to one of the diagrams on the right,
depending on whether the TP75 has been set up for 7 day or 5/2 day
mode.
Use the +, -,
,
, NEXT buttons to
alter the events as required,
OR
If the previous day's programme is
to be repeated, press COPY to
repeat those events with just one
button press.
(Pressing COPY when in 5/2 day
mode will repeat the events
programmed for days 1 to 5 at the
weekend).
Use DAY and NEXT to check all the
events programmed, using the +, -
,
,
, NEXT buttons to make
alterations to each event as
necessary.
When all the events for every day
are as required, press PROG to
return to RUN mode, with the colon
blinking.
The heating system will now be
controlled to provide the temperatures programmed.
Refer to the USER'S GUIDE for details of the manual over-rides
available during day to day operation.
+
PROG
DAY
R/S
-
NEXT
COPY
button to lower the control
button until
7 day mode
+1 HR
+2 HR
+3 HR
5/2 day mode
+1 HR
+2 HR
+3 HR
+1 HR
+2 HR
+3 HR
1

Advertisement

loading

Summary of Contents for Danfoss TP75H

  • Page 1: Setting The Clock

    Electronic Programmable Room Thermostats TP75H with integral sensor, for high current applications TP75HA with remote sensor, for high current applications SETTING INSTRUCTIONS SETTING THE CLOCK After the recessed R/S (reset) button +1 HR +2 HR has been pressed the display appears +3 HR as shown, with the colon blinking, and all the factory pre-set conditions will...
  • Page 2 NOTES ON SETTING EVENT FACTORY PRE-SET PROGRAMME TIMES The TP75H range of programmable room thermostats are provided with a factory pre-set programme of switching times and temperatures, so that, once the clock has been set and the If, during the event checking and setting TP75H returned to the RUN mode, the heating system will be controlled at the times and to the procedure, no buttons are pressed for temperatures of the pre-set programme, as shown in the following table and indicated by the...
  • Page 3: Display Elements

    Electronic Programmable Room Thermostats TP75H with integral sensor, for high current applications TP75HA with remote sensor, for high current applications USER'S GUIDE How to: Select a 12 hour or a 24 hour clock display. Select a °C or a °F temperature display. Change between Winter Time and Summer Time at the press of a button.
  • Page 4: User Overrides

    Danfoss Randall can accept no responsibility for possible errors in catalogues, brochures and other printed material, and reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.

This manual is also suitable for:

Tp75ha