Charcoal Filters - Electrolux CH 910 Instruction Book

Electrolux plc electrolux cooker hood instruction book ch 910
Hide thumbs Also See for CH 910:
Table of Contents

Advertisement

Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply.

Charcoal Filters

In the recirculation mode the charcoal fi lters absorb smells and unwanted odours.
Enabling the alarm signal
• In Recirculation Version Hoods, the Filter saturation Alarm must be enabled at the time of installation or later.
• Switch off the lights and the motor.
• Disconnect the mains power supply to the hood by removing the motor unit power supply cable connector,
switching off the power supply at the Mains or turning the Main switch off.
• Restore the connection, pressing and holding T2.
• Release the touch control, touch controls L, T2 and F will light up normally.
• Within 3 seconds press the touch control F until the key itself fl ashes to confi rm as follows:
• 2 fl ashes – Charcoal odour Filter saturation Alarm ENABLED
• 1 fl ash - Charcoal odour Filter saturation Alarm DISABLED
This fi lter cannot be washed or regenerated, and must be replaced when the F touch control starts to fl ash, or at least
once every 4 months. The alarm is only triggered when the motor is on.
To Remove/Replace the Charcoal Filters
• Remove the metal grease fi lters
• Remove the saturated activated carbon fi lter by
releasing the fi xing hooks
• Fit the new fi lter by hooking it into its seating
• Replace the metal grease fi lters.
This appliance can be a possible fi re
hazard if the grease and charcoal fi lters
are not cleaned and replaced as recommended.
Alarm signal reset
• Stop the motor.
• Press the touch control F for at least 4 seconds, until
the touch control T1 fl ashes.
Changing the Light halogen
• Remove the 2 screws fi xing the Lighting support, and
pull it out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure
that the two pins are properly inserted in the lamp
holder socket holes.
• Replace the Support, fi xing it in place with the two
screws removed as above.
MAINTENANCE AND CLEANING
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ch 910x

Table of Contents