Canon FACSIMILE BASIC 2000 Service Manual page 253

Table of Contents

Advertisement

6.8.3 Details of FCF
The FCF for each signal is determined as shown in the following table.
Table 5-14 Correspondence between Signal Name and FCF
Initial identification
Transmit command
Receive command
Pre-message responses
Post-message
Commands
Post-message responses
Others
(Note)
According to the
The side that receives DIS first X
the other side X
that is, In regular communications:the calling side:X = 1
In polling:
• Ordinarily, X is "0" and becomes "1" when DIS is received.
This also implies protection against echo.
• X may not be a factor in cases of other manufacturer's facsimiles.
G3 FACSIMILE COMMUNICATIONS
Signal
Name
NSF
00000100
CSI
00000010
DIS
00000001
NSC
10000100
CIG
10000010
DTC
10000001
NSS
X1000100
TSI
X1000010
DCS
X1000001
CFR
X0100001
FTT
X0100010
EOM
X1110001
MPS
X1110010
EOP
X1110100
MCF
X0110001
RTP
X0110011
RTN
X0110010
DCN
X1011111
ITU-T
recommendation:
"1"
"0"
the called side:X = 0
the calling side: X = 0
the called side:X = 1
FCF
Remarks
FIF follows right
after.
FIF does not fol-
low.
5–111
1
2
3
4
5
6
ït
çi

Advertisement

Table of Contents
loading

This manual is also suitable for:

Basic 2000

Table of Contents