The Scanner Fails To Move Forward; The Registration Roller Fails To Rotate - Canon NP6512 Service Manual

Hide thumbs Also See for NP6512:
Table of Contents

Advertisement

18 The scanner fails to move forward.

Cause
Step
Cable
1
Scanner path
2
Composite
3
power
supply PCB
Pre-registra-
4
tion roller
paper sensor
(Q751)
Scanner/lens
5
drive motor
(M2)
DC control-
ler PCB

19 The registration roller fails to rotate.

Cause
Step
Main motor
1
(M1)
Pre-registra-
2
tion roller
paper sensor
(Q751)
Registration
3
roller spring
clutch
Registration
4
clutch
solenoid
(SL2)
DC control-
ler PCB
COPYRIGHT © 1999 CANON INC.
Checks
Is the scanner drive cable routed
correctly?
Is the scanner rail soiled?
Move the scanner by hand. Does it
move smoothly?
Set the meter range to 30 VDC, and
connect the meter probes to J202-2 (+)
and -1 (-) on the composite power
supply PCB. Is the meter reading
about 24 V?
Is the pre-registration roller paper
sensor (Q751) normal? (For instruc-
tions on how to check the
photointerrupers, see p. 11-51.)
Replace the scanner/lens drive motor
(M2). Is the problem corrected?
Checks
Does the main motor (M1) start to
rotate when the Copy Start key is
pressed?
Is the pre-registration roller paper
sensor (Q751) normal? (For instruc-
tions on how to check the
photointerrupers, see p. 11-51.)
Does the registration clutch solenoid
(SL2) turn on for a moment after the
Copy Start key is pressed?
Set the meter range to 30 VDC. Does
the voltage between J109-6 (+) and -5
(-) on the DC controller PCB change
to about 24 V for a moment after the
Copy Start key is pressed?
CANON NP6512/6612/7120/7130/7130F REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
YES/NO
NO
Route the cable
correctly.
NO
Check the surface of
the scanner rail for
dirt, foreign matter, or
object which may
interfere.
NO
See "DC power fails to
turn on."
NO
Check the wiring from
J108 on the DC
controller PCB to
Q751; if normal,
replace Q751.
YES
End.
NO
Replace the DC
controller PCB.
YES/NO
NO
See "The main motor
fails to rotate."
NO
Check the wiring from
J108 on the DC
controller PCB to
Q751; if normal,
replace Q751.
NO
Check the position of
the solenoid; if nor-
mal, check or replace
the control ring.
YES
Check the wiring from
J109 on the DC
controller PCB to SL2;
if normal, replace SL2.
NO
Replace the DC
controller PCB.
Action
Action
11-73