Electrolux RM 122F Operating And Installation Instructions page 6

Type a310 k refrigerator, bottled gas and 12 / 230 volt operation
Table of Contents

Advertisement

Flue Venting Kit
The flue gasses must be vented directly to the outside air. Only the ELECTROLUX flue venting kit
(supplied with the refrigerator in the United Kingdom) is recommended for this purpose. It consists of the
following parts:
Flue Top Complete - G
Flue Outlet Cover Plate -B
Exhaust Gas Pipe Complete - F
Srew-Self Tapping, No. 6 ¼" – H
The flue top (G) is in the form of a lazy "T" and incorporates an air-break to minimise the possibility of
flame extinction due to draughts.
Leading from the flue-top, the extension tube (F) has to pass through the wall of the vehicle to direct the
flue gasses to the outside. Care must be taken in determining the positions of the centres of the holes in
the inner and outer skins of the caravan wall to accept the extension tube. As the amount of space
between the back of the refrigerator and the inside wall of the vehicle as well as the thickness of the wall,
may vary for each type of caravan, it is not possible to give actual dimensions therefore each case must be
considered carefully before starting to make the opening. Take particular care to ensure that the angle is
correct so that when in position, the extension tube will line up accurately with the sloping part of the flue-
top.
The opening must be large enough to allow the insertion of a layer of non-combustible material around the
extension tube as shown in fig. 7. but the opening in the outer skin must not exceed 70mm (2 ¾") in
diameter, otherwise the flange on the flue outlet may not cover it completely.