Electrical Connection U.k - Miele W 829 Operating Instructions Manual

Table of Contents

Advertisement

Electrical connection U.K.

All electrical work should be carried out
only by a suitably qualified and compe-
tent person, in strict accordance with
national and local safety regulations.
The appliance is supplied with a mains
cable with moulded plug for connection
to a 230-240V mains supply. The volt-
age, rated load and fuse rating are
given on the data plate. Please ensure
these match the household mains sup-
ply.
Connection should be made via a
fused plug and suitable switched
socket which is easily accessible after
installation. For extra safety it is advis-
able to install a residual current device
(RCD), with a trip current of 30 mA. Do
not connect via an extension lead.
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live
Where it is necessary to change plugs,
if the colours of the wires in the mains
lead of this appliance do not corre-
spond with the coloured markings
identifying the terminals of your plug,
proceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or col-
oured green, or green and yellow.
The wire which is coloured blue must
be connected to the terminal in the
plug which is marked with the letter N
or coloured black.
The wire which is coloured brown must
be connected to the terminal in the
plug which is marked with the letter L
or coloured red.
WARNING: THIS APPLIANCE
MUST BE EARTHED
Ensure power is not supplied to the ap-
pliance while installation work is being
carried out.
Installation
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents