(9) Signal isolation
Code 1
90
90
(10) Video signal reception
Code 1
A0
A0
A0
A0
A0
A0
A0
A0
A8
A9
AA
(11) General communications-related
Code 1
B0
B0
B0
B0
Code 2
01
Unable to detect video signals and commands within 6
seconds after CFR is transmitted.
02
Received PPS containing invalid page count or block
count.
Code 2
03
Error correction sequence not terminated even at the final
transmission speed for fallback.
11
Receive buffer empty. (5-second time-out)
12
Receive buffer full during operation except receiving into
memory.
13
Decoding error continued on 500 lines.
14
Decoding error continued for 10 seconds.
15
Time-out: Five seconds or more for one-line transmission.
16
RTC not found and carrier OFF signal detected for 6
seconds.
17
RTC found and command detected for 60 seconds.
01
RTN, PIN, or ERR received at the calling terminal. *
01
RTN, PIN, or ERR received at the called terminal. *
18
Receive buffer full during receiving into memory.
Code 2
01
Polarity inversion detected.
02
Unable to receive the next-page data.
03
Unable to receive polling even during turn-around trans-
mission due to call reservation.
04
PC interface error.
VI – 9