GE GTDS855GDMC Installation Instructions Manual page 9

Ge 7.8 cu. ft. capacity gas dryer with stainless steel drum and steam
Hide thumbs Also See for GTDS855GDMC:
Table of Contents

Advertisement

10
BATHROOM OR BEDROOM INSTALLATION
The dryer MUST be vented to the outdoors. See EXHAUST
INFORMATION section 6.
The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL FUEL GAS CODE,
ANSI Z223
MOBILE OR MANUFACTURED HOME
11
INSTALLATION
Installation must conform to the MANUFACTURED HOME
CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART
32-80 or, when such standard is not applicable, with
AMERICAN NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
The dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 6).
The vent MUST NOT be terminated beneath a mobile or
manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other duct,
vent, or chimney.
Do not use sheet metal screws or other fastening devices
which extend into the interior of the exhaust vent.
Provide an opening with a free area of at least 25 sq. in.
for introduction of outside air into the dryer room.
12
GARAGE INSTALLATION
DRYER EXHAUST TO LEFT OR BOTTOM
13
CABINET
WARNING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with cover plate
Electrical Shock
Failure to do so may result in electrical
Hazard
shock or lacerations.
* The internal elbow must be included in the total elbow count.
: the long vent model (GTDL740GDWW) is capable of rear
NOTE
and bottom venting only.
Installation Instructions
(IF ALLOWED BY LOCAL CODES)
ated
(Kit WE1M454).
Detach and remove the bottom or left side knockout as
desired. Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dryer. Protect sharp edges
around the knockout and exhaust opening with the tape.
B
Cut the duct as shown and keep portion A.
TAB LOCATION
BEND TAB
o
UP 45
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
ADDING NEW DUCT
FIXING
HOLE
PORTION "A"
RIGHT OR
LEFT SIDE
EXHAUST
Reconnect the cut portion (A) of the duct to the blower
housing. Make sure that the shortened duct is aligned with
the tab in the base. Use the screw saved previously to secure
the duct in place through the tab on the appliance base.
9
FIXING HOLE
A
14"

Advertisement

Table of Contents
loading

Table of Contents