Error Message SENSOR-3-TEMP_CRITICAL: System sensor "d" has exceeded CRITCAL
temperature thresholds
Error Message SENSOR-3-TEMP_NORMAL: "s" temperature sensor is now normal
Error Message SENSOR-3-TEMP_SHUTDOWN: Shuting down the system because of dangerously
HIGH temperature at sensor "d".
Error Message SENSOR-3-TEMP_WARNING: "s" temparature sensor "d" has exceeded WARNING
temperature thresholds
Error Message SENSOR-3-VOLT_CRITICAL: System sensor "d" has exceeded CRITCAL voltage
thresholds
OL-14209-01
One of the measured environmental test points exceeds the extreme threshold.
Explanation
Correct the specified condition, or the system may shut itself down as a
Recommended Action
preventive measure. Enter the show environment all to help determine if this is due to temperature
or volatage condition. If this is a critical temperature warning, please ensure that the router fans are
are operating and that the room cooling and air-conditioning are functioning. This condition could
cause the system to fail to operate properly.
One of the measured environmental test points is under normal operating temperature.
Explanation
Recommended Action
None required
One of the measured environmental test points exceeds the operating temperature
Explanation
environment of the router.
Recommended Action
Investigate the cause of the high temperature.
Explanation
One of the measured environmental test points exceeds the warning threshold.
Closely monitor the condition and correct if possible, by cooling the
Recommended Action
environment.
One of the measured environmental test points exceeds the extreme voltage threshold.
Explanation
Correct the specified condition, or the system may shut itself down as a
Recommended Action
preventive measure. Enter the show environment all to help determine if this is due to volatage
condition. This condition could cause the system to fail to operate properly.