Dc Application - Honda EMS4000 Owner's Manual

Hide thumbs Also See for EMS4000:
Table of Contents

Advertisement

DC application
The DC terminals
may be used for charging 12 volt automotive-type
batteries
only.
m
Batteries
produce
explosive
gases. Keep sparks, flames,
and
cigarettes
away.
To prevent
the possibility
of creating
a spark near the
battery,
connect
charging cables first to the battery, then to the generator,
and disconnect
cables first at the generator.
CAUTION:
l
Do not attempt to start an automobile
engine while the generator is still con-
nected to the battery. The generator may be damaged.
l
Connect the positive battery terminal to the positive generator terminal.
Do
not reverse the charging cables, or serious damage to the generator and/or
battery may occur.
NOTE:
l
The DC terminals may be used while the AC power is in use.
l
An overloaded
DC circuit
will trip the DC circuit
protector
(push button
comes out). If this happens, wait a few minutes before pushing the circuit
protector
to resume operation.
NEGATIVE'
POSITIVE
TERMINAL
TERMINAL,
(BLACK)
(RED)