ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit's SET button. Horizontal (right-left)
airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.
Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction
louvers are stopped.
Vertical Air Direction Adjustment
Press the SET button (Fig. 6 Q).
Each time the button is pressed, the air direction range will change as follows:
1
Types of Air flow Direction Setting:
1,2,3
: During Cooling/Dry modes
4,5,6,7 : During Heating mode
1,2,3,4,5,6,7 : During Fan mode
The Remote Control Unit's display does
not change.
● Use the air direction adjustments within the ranges shown above.
● The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Heating mode
● During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this pe-
riod.
Right-Left Adjustment
Adjust the Right-Left louvers.
● Move the Right-Left louvers to adjust air flow in the direction you prefer.
knob(three places)
11
2
3
4
5
: Downward flow 7
knob
R DANGER!
● Never place fingers or foreign objects in-
6
7
R DANGER!
● When adjusting the Right-Left Louvers, it
side the outlet ports, since the internal fan
operates at high speed and could cause
personal injury.
● Always use the Remote Control Unit's
SET button to adjust the vertical airflow
louvers. Attempting to move them
manually could result in improper op-
eration; in this case, stop operation and
restart. The louvers should begin to
operate properly again.
● During use of the Cooling and Dry
modes, do not set the Air Flow Direc-
tion Louvers in the Heating range (4 -
7) for long periods of time, since wa-
ter vapor may condense near the out-
let louvers and drops of water may drip
from the air conditioner. During the
Cooling and Dry modes, if the Air Flow
Direction Louvers are left in the heat-
ing range for more than 30 minutes,
they will automatically return to posi-
tion 3.
● When used in a room with infants, chil-
dren, elderly or sick persons, the air
direction and room temperature
should be considered carefully when
making settings.
is necessary to stop the Air-Conditioner
first and make sure that it stops completely
before adjusting the direction.