The number of configured channels and licensed channels are displayed.
AltiServ is set by default to support 60 SIP extension channels. You can change the
number of SIP extension channels and tie-trunk channels, up to 400. If you change the
numbers in this dialog box, you must shut down and restart the switching and gateway
services for this change to take effect. When the services restart, the new configuration
appears in the Currently Configured Channels fields.
The SIP Trunking Configuration button opens the SIP Trunking Configuration dialog
box. (See "SIP Trunk Properties" on page 143.)

Configuring the H323SP Board

Double-clicking an H323SP board in Boards view and then clicking the Board
Configuration button opens this dialog box:
Figure 18. H323 Configuration
You can change the following parameters:
FastStart Enabled: The FastStart Enabled option reduces the number of H.323
messages to be sent between two H.323 devices when initiating a call, thus reducing
the time needed to establish a call. There may be a compatibility issue with firewall
or NAT devices, if you select this option.
Max Tie-Trunk Channel: Sets the maximum number of trunk channels for this
board in increments of 4, from 4 to 96. You need to reboot the AltiWare system after
the maximum trunk channel number is changed.
If you change the
maximum number of
trunk channels, you need
to reboot the AltiWare
system.