Table 79. Post Error Beep Codes - Intel SC5650BCDP Technical Product Specification

Technical product specification
Hide thumbs Also See for SC5650BCDP:
Table of Contents

Advertisement

Appendix C: POST Error Messages and Handling
Beeps
Error Message
3
Memory error
The following Beep Codes are from the BMC, and are controlled by the Firmware team. They are listed here
for convenience.
1-5-2-1
CPU: Empty slot /
population error.
1-5-4-2
Power fault: DC
power
unexpectedly lost
(power good
dropout)
1-5-4-4
Power control fault
(Power good
assertion timeout)
In case of POST error(s) that are listed as Major, the BIOS enters the error manager and waits
for the user to press an appropriate key before booting the operating system or entering the
BIOS Setup.
The user can override this option by setting the POST Error Pause option as disabled on the
BIOS setup Main screen. If this option is disabled, the system boots the operating system
without user intervention. The default is disabled.
138

Table 79. POST Error Beep Codes

POST Progress Code
Multiple
System halted because a fatal error related to the
memory was detected.
CPU sockets are populated incorrectly – CPU1 must be
N/A
populated before CPU2.
Power unit sensors – power unit failure offset.
N/A
Power unit sensors – soft power control failure offset.
N/A
Intel order number: E42249-009
Intel® Server Board S5500BC TPS
Description
Revision 1.8

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC5650BCDP and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Sc5650bc

Table of Contents

Save PDF