Download Print this page
Electrolux EI30GF35JS Service Data Sheet
Electrolux EI30GF35JS Service Data Sheet

Electrolux EI30GF35JS Service Data Sheet

Gas range with es 1030/1031 electronic oven control
Hide thumbs Also See for EI30GF35JS:

Advertisement

Available languages

Available languages

SERVICE DATA SHEET -
Gas Range with ES 1030/1031 Electronic Oven Control
NOTICE - This service data sheet is intended for use by persons having electrical
and mechanical training and a level of knowledge of these subjects generally
considered acceptable in the appliance repair trade. The manufacturer cannot be
responsible, nor assume any liability for injury or damage of any kind arising from
the use of this data sheet.
Safe servicing practices
To avoid the possibility of personal injury and/or property damage, it is important that safe
servicing practices be observed. The following are examples, but without limitation, of
such practices.
1.
Before servicing or moving an appliance remove power cord from electrical outlet,
trip circuit breaker to OFF, or remove fuse.
2.
Never interfere with the proper installation of any safety device.
3.
GROUNDING: The standard color coding for safety ground wires is GREEN or
GREEN WITH YELLOW STRIPES. Ground leads are not to be used as current
carrying conductors. It is extremely important that the service technician
reestablish all safety grounds prior to completion of service. Failure to do so
will create a potential safety hazard.
4.
Prior to returning the product to service, ensure that:
• All electric connections are correct and secure.
• All electrical leads are properly dressed and secured away from sharp edges, high-
temperature components, and moving parts.
Electronic oven control (EOC) & jumper connection locations
1
1
P23
EOC jumper connections
PIN 6-LOCK SWITCH
P23
P8
PIN 5-DOOR SWITCH
PIN 10-N
PIN 4-COMMON
PIN 8-OVEN LAMP
PIN 2-OVEN PROBE
PIN 4-CONV FAN MOTOR
PIN 1-OVEN PROBE
SINGLE CAVITY GAS ELUX-C EOC 1030 MEMBRANE KEYPAD MATRIX
CONNECTOR-PIN #
Pxx-1
Pxx-2
Pxx-3
Pxx-7
CONNECT
LOOP
CONVECTION
Pxx-11
ONE
BAKE
CONVERT
Pxx-12
FOUR
BROIL
FAVORITES
SLOW
CONVECTION
Pxx-13
SEVEN
COOK
ROAST
CONVECTION
KEEP
Pxx-14
START
BAKE
WARM
CONVECTION
RAPID
Pxx-15
CANCEL
BROIL
PREHEAT
NOT IN MEMBRANE
DOOR SWITCH, MDL SWITCH, RACK SWITCH, ETC...
IMPORTANT
DO NOT REMOVE THIS BAG OR DESTROY THE
CONTENTS
WIRING DIAGRAMS AND SERVICE INFORMATION
REPLACE CONTENTS IN BAG
ENCLOSED
p/n 316905084 EN/FR (1207)
• All uninsulated electrical terminals, connectors, heaters, etc. are adequately
spaced away from all metal parts and panels.
• All safety grounds (both internal and external) are correctly and securely
reassembled.
Oven Calibration
Set the electronic oven control for normal baking at 350°F. Obtain an average oven
temperature after a minimum of 5 cycles. Press cancel keypad to end bake mode.
Temperature Adjustment
1.
While in a non-cooking mode, press and hold the bake key pad for 6 seconds.
2.
The current calibration offset (temperature adjustment) should appear in the
temperature display.
3.
Use the number key pads (0-9) to enter the desired amount of adjustment (up to
35°F).
4.
Press the bake key to change the sign of the adjustment to a (-) if necessary. A
positive adjustment will not display a sign.
5.
Once the desired adjustment (-35° to 35° F) has been entered, press the start
key pad to accept the change or the cancel key pad to reject the change.
NOTE: Changing calibration affects all Baking modes. The adjustments made will not
change the self-cleaning temperature.
P8
1
P22
P21
P21
PIN 8-LOCK MOTOR
PIN 6-CONV ELEMENT
PIN 4-BAKE IGNITER
PIN 2-BROIL IGNITER
Pxx-4
Pxx-5
Pxx-6
Pxx-8
Pxx-9
COOK
CONTROL
NINE
TIME
LOCK
MY
END
COOKTOP
SIX
TIME
LOCK
SET
OVEN
THREE
CLOCK
LIGHT
TIMER
ZERO
TWO
ON/OFF
SELF
CONNECT
EIGHT
FIVE
CLEAN
LOOP
EOC = Electronic Oven Control
VSC = Variable Speed Control
PS
= Power Supply board (PS1, PS2, etc.)
RTD = Resistance Temperature Device. (Temp Probe or Temp Sensor)
TCO = Thermal Cut Out also "Thermo Disc" or "Thermal Limiter"
Electronic Oven Control Fault Code Descriptions
Fault
Likely failure
Code
condition/cause
Runaway temperature.
F10
Oven heats when no cook
cycle is programmed.
F11
Shorted keypad or selector
switch.
F12
EOC Internal software error
or failure.
F13
F14
Keyboard tail failure.
F17
EOC Internal hardware error
of failure.
F18
F30
Open oven sensor probe
circuit.
F31
Shorted oven sensor probe
circuit.
F42
EOC internal software
configuration error.
Internal signal voltage error.
F50
Display communication error.
F51
F60
EOC oven temperature.
Higher than normal
temperature detected on the
EOC board.
F64
Time Base failure. The EOC
cannot determine if
connected to 50Hz or 60Hz
power supply.
F65
Keyboard short circuit or
internal EOC failure.
F66
EOC internal power supply
failure.
F68
High voltage condition. L1 or
L2 may be crossed with
Neutral on incoming PS.
F90
Door lock motor or latch
circuit failure.
Pxx-10
F91
F95
Temperature °F (°C)
32 ± 1.9 (0 ± 1.0)
75 ± 2.5 (24 ± 1.3)
250 ± 4.4 (121 ± 2.4)
350 ± 5.4 (177 ± 3.0)
450 ± 6.9 (232 ± 3.8)
550 ± 8.2 (288 ± 4.5)
650 ± 9.6 (343 ± 5.3)
900 ± 13.6 (482 ±7.5)
Probe circuit to case ground
Suggested Corrective Action
If Oven is cold:
1. If fault code is present with cold oven, test oven temperature sensor probe circuit resistance. Use RTD scale found in the tech sheet.
2. Replace probe or repair wiring connections if defective.
3. If temperature sensor probe circuit is good but fault code remains when oven is cold replace the EOC.
If Oven is overheating:
1. If oven is severely overheating/heating when no cook cycle is programmed, test oven temperature sensor probe circuit resistance
using the RTD scale found in the service tech sheet. Also verify that the temperature sensor probe in properly installed in the oven
cavity.
2. Disconnect power from the range, wait 30 seconds and reapply power. If oven continues to heat when the power is reapplied, replace
the EOC. NOTE: Severe overheating may require the entire oven to be replaced should damage be extensive.
1. Reset power supply to range - Disconnect power, wait 30 seconds and reapply power.
2. Check/reseat ribbon harness connections between touch panel and EOC.
3. Test keyboard circuits using test matrix. Replace touch panel if defective.
4. If keyboard circuits check correctly, replace the EOC.
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.
1. Check/reseat ribbon harness connections between keyboard touch panel and EOC.
2. Test keyboard circuits using test matrix (below). Replace touch panel if defective.
3. If keyboard circuits check correctly, replace EOC.
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.
1. (F30) Check resistance at room temperature and compare to RTD Sensor resistance chart. If resistance is correct replace the EOC. If
resistance does not match the RTD chart, replace RTD sensor probe. Check sensor wiring harness between EOC and sensor probe
connector.
2. (F31) Check resistance at room temperature. If less than 500 ohms, replace RTD sensor probe. Check for shorted sensor probe
harness between EOC and probe connector. If resistance is correct, replace the EOC.
Usually this failure code would only appear if the EOC has been replaced with an incorrect version. Verify that the correct replacement
part number is being used.
Disconnect power, wait 30 seconds and reapply power. If fault returns when power is reapplied, replace EOC.
1. Verify proper assembly of backguard panel. Check for damaged or loose panels, brackets, endcaps, etc.
2. Check for blocked ventilation slots in control panel rear cover.
3. Inspect oven vent for proper assembly and air flow.
4. Verify operation of cooling fan (if present).
Confirm that range is connected to proper power source (50Hz or 60Hz). Generators or other portable power supplies and solar grids, etc.,
may not provide proper power supply. If power source is correct, replace the EOC.
1. Test keyboard circuits using test matrix. Replace touch panel if defective.
2. If keyboard circuits check correctly, replace the EOC
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up, replace EOC.
1. Verify proper incoming line voltage and polarity of L1, L2 and Neutral power supply connections at range terminal block.
2. If power supply voltage and polarity are correct, replace EOC.
If lock motor runs:
1. Test continuity of wiring between EOC and lock switch on lock motor assy. Repair if needed.
2. Advance motor until cam depresses the plunger on lock motor switch. Test continuity of switch contacts. If switch is open replace
lock motor assembly.
3. If motor runs and switch contacts and wiring harness test correctly, replace the EOC.
If lock motor does not run:
1. Test continuity of lock motor windings. Replace lock motor assembly if windings are open.
2. Test lock motor operation by using a test cord to apply voltage. If motor does not operate, replace lock motor assy.
3. If motor runs with test cord, check continuity of wire harness to lock motor terminals. If harness is good replace the EOC.
RTD SCALE
Resistance (ohms)
1000 ± 4.0
1091 ± 5.3
1453 ± 8.9
1654 ± 10.8
1852 ± 13.5
2047 ± 15.8
2237 ± 18.5
2697 ± 24.4
Open circuit/infinite resistance
EOC Relays - ES1030/1031 Gas Range

Advertisement

loading

Summary of Contents for Electrolux EI30GF35JS

  • Page 1 SERVICE DATA SHEET - Electronic Oven Control Fault Code Descriptions Gas Range with ES 1030/1031 Electronic Oven Control Fault Likely failure Suggested Corrective Action Code condition/cause NOTICE - This service data sheet is intended for use by persons having electrical •...
  • Page 2 General Troubleshooting Diagram General Troubleshooting Schematic...
  • Page 3 Description des codes d’erreurs du régulateur électronique de four FICHE DE RÉPARATION - Cuisinière à gaz avec régulateur électronique de four ES 1030/1031 Code Cause probable Mesure corrective suggérée d’err. du problème AVIS : Cette fiche de réparation a été conçue pour être utilisée par des personnes •...
  • Page 4 Schéma de dépannage général Schéma de dépannage général...