Troubleshooting Flowcharts - HP ML150 - ProLiant - G6 User Manual

Proliant ml100 series server
Hide thumbs Also See for ML150 - ProLiant - G6:
Table of Contents

Advertisement

Online/activity
LED (green)
On, off, or
flashing
On, off, or
flashing
On
On
Flashing regularly
(1 Hz)
Flashing regularly
(1 Hz)
Flashing
irregularly
Flashing
irregularly
Off
Off
Off

Troubleshooting flowcharts

To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section,
"Start diagnosis flowchart (on page 55)," and follow the appropriate diagnostic path. If the other
flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis
flowchart (on page 55)." The General diagnosis flowchart is a generic troubleshooting process to be used
when the problem is not server-specific or is not easily categorized into the other flowcharts.
The available flowcharts include:
Start diagnosis flowchart (on page 55)
General diagnosis flowchart (on page 55)
Server power-on problems flowchart
POST problems flowchart (on page 59)
Fault/UID LED
Interpretation
(amber/blue)
Alternating amber
The drive has failed, or a predictive failure alert has been
and blue
received for this drive; it also has been selected by a
management application.
Steadily blue
The drive is operating normally, and it has been selected by a
management application.
Amber, flashing
A predictive failure alert has been received for this drive.
regularly (1 Hz)
Replace the drive as soon as possible.
Off
The drive is online, but it is not active currently.
Amber, flashing
Do not remove the drive. Removing a drive may terminate the
regularly (1 Hz)
current operation and cause data loss.
The drive is part of an array that is undergoing capacity
expansion or stripe migration, but a predictive failure alert has
been received for this drive. To minimize the risk of data loss,
do not replace the drive until the expansion or migration is
complete.
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, erasing, or it is part of an array that is
undergoing capacity expansion or stripe migration.
Amber, flashing
The drive is active, but a predictive failure alert has been
regularly (1 Hz)
received for this drive. Replace the drive as soon as possible.
Off
The drive is active, and it is operating normally.
Steadily amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.
Amber, flashing
A predictive failure alert has been received for this drive.
regularly (1 Hz)
Replace the drive as soon as possible.
Off
The drive is offline, a spare, or not configured as part of an
array.
("Power-on problems
flowchart" on page 57)
Troubleshooting 54

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml110 g6Proliant ml150 g6

Table of Contents