MVP MANUAL
(12) Full dot number compensation [HFD command]
Input :
HFDddd
Explanation : • d
d
d
:Compensation data 0 to 254
1
2
3
• Corrects the preset sampling clock.
• Vertical bit lines can be erased by executing the HFD command.
• The HFD and HPS data are correlated and have limited values.
Figure: Bit Lines which can be Erased by HFD Execution
(13) Freeze frame Y:ON N:OFF [FZY, FZN commands]
Input :
FZY, FZN
Explanation : • Continuously outputs the image the moment the FZY is executed. This is canceled by FZN.
• Whether the state is FZY or FZN can be determined by executing the STS command.
• Do not perform position adjustments in the FZY state.
(14) Vertical filter ON/OFF [DSY, DSN, DSX commands]
Input :
DSY, DSN, DSX
Explanation : • Converts the vertical line number so that the computer images can be displayed fully on the
monitor.
• The conversion rate preset by the LCV command can be changed. (Refer to LCV command.)
• Whether the state is DSY or DSN can be determined by executing the STS command.
480 vertical lines
Figure: Example of DSY and DSN Executions (MAC 6-5 Conversion Example)
• The DSX is a command which makes the V.FIL switch on the rear of the MVP effective.
166
Bit lines
DSY
DSN
400 vertical lines