3. INSTRUCTIONS FOR USING A COMPUTER AS A TERMINAL
<When the IBM-PC/AT is used>
¶ Use commercially available communications software.
¶ Use PC-DOS internal commands (TYPE, COPY, etc.)
Pay attention to use because only one-way transmission of data is possible in this case.
<With the PC-9800 series>
¶ Use commercially available communications software (CCT 98, etc.)
¶ Use the MS-DOS commands (TYPE, COPY, etc.)
Pay attention to use because only one-way transmission of data is possible in this case.
<Example of a program GW-BASIC>
100 OPEN "COM1:9600, N, 7, 1" AS#1
110 ON COM1 GOSUB
120 COM1 ON
130
LOOP
140
A$=INKEY$:IF A$="" THEN
150
PRINT#1,A$;
160
GOTO
170
RCV
180
IF LOC(1)<>0 THEN PRINT INPUT$(LOC(1),#1);
190 RETURN
<Communication mode settings in use of CCT98>
Set the CCT98 communication mode before executing the MVP commands.
After starting up CCT98,
F6 ...................... Enter the parameter setting mode.
Set the following items as follows.
Communication speed
Character length
Stop bit
Parity bit
Character code
Transmission carriage return code
Reception carriage return code
SI/SO control
X control
* Problems may occur in signal transfer at 2400 bps when adjusting the optional variable scan board.
* Refer to the CCT98 manual for how to use the CCT98.
142
RCV
LOOP
LOOP
2400 4800 9600 19200
7 bits 8 bits
1 bit
None ODD EVEN
NEC
CR
CR
None
None
................................ MVP setting at shipment
2 bits
Selectable
Fixed