ITEM
Type
Material
Motor Type
Input Power
Output Power
Fan
Fan Speed
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
W
W
Q-Lo (Cool/Heat)
rpm
Lo (Cool/Heat)
rpm
Me (Cool/Heat)
rpm
Hi (Cool/Heat)
rpm
SHi (Cool/Heat)
rpm
mm
Unit
ø
V
Hz
W
A
A
%
A
m
7
INDOOR UNIT
Cross-Flow Fan
ASG20K1
Transistor (8-pole)
—
30
780 / 1090
920 / 1150
1175 / 1325
1430 / 1500
1470 / 1540
Aluminium (Pre Coat)
Slit Fin
2 x 15 x 21
610 x 315 x 25.4
Polypropelene
One-Touch
Single
230
50
Cooling; 915 (185 ~ 1180)
Heating; 1260 (175 ~ 1890)
5.8
Cooling; 4.2
Heating; 5.8
Cooling; 95
Heating; 95
8.7
—
—
Electronic Control
Electronic Control
OUTDOOR UNIT
Propeller Fan
PP
Induction (6-pole)
70
30
—
—
—
830 / —
—
Aluminium
Corrugated Fin
2 x 24 x 17
36.4 x 504 x 713
684
—
—