2.2.
Sensible Capacity Chart
CS-CE7GKEW CU-CE7GKE
230V
Indoor wet
bulb temp.
TC
17.0°C
2.03
19.0°C
19.5°C
2.23
22.0°C
2.43
CS-CE9GKEW CU-CE9GKE
230V
Indoor wet
bulb temp.
TC
17.0°C
2.58
19.0°C
19.5°C
2.83
22.0°C
3.09
CS-CE12GKEW CU-CE12GKE
230V
Indoor wet
bulb temp.
TC
17.0°C
3.47
19.0°C
19.5°C
3.81
22.0°C
4.15
TC
-
Total Cooling Capacity (kW)
SHC
-
Sensible Heat Capacity (kW)
IP
-
Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C
30
35
SHC
IP
TC
SHC
1.54
0.44
1.90
1.48
2.05
1.61
0.45
2.09
1.55
1.67
0.46
2.27
1.61
30
35
SHC
IP
TC
SHC
1.96
0.54
2.41
1.88
2.60
2.05
0.55
2.65
1.97
2.12
0.56
2.88
2.04
30
35
SHC
IP
TC
SHC
2.63
0.84
3.24
2.52
3.50
2.76
0.86
3.56
2.65
2.86
0.87
3.88
2.75
Outdoor Temp. (°C)
40
IP
TC
SHC
0.47
1.77
1.42
0.48
0.48
1.94
1.49
0.49
2.12
1.55
Outdoor Temp. (°C)
40
IP
TC
SHC
0.58
2.24
1.80
0.59
0.59
2.46
1.89
0.60
2.68
1.97
Outdoor Temp. (°C)
40
IP
TC
SHC
0.91
3.02
2.43
0.92
0.92
3.31
2.55
0.94
3.61
2.65
20
46
IP
TC
SHC
IP
0.51
1.61
1.35
0.55
0.52
1.77
1.42
0.56
0.52
1.92
1.48
0.57
46
IP
TC
SHC
IP
0.62
2.04
1.71
0.67
0.63
2.24
1.80
0.68
0.64
2.44
1.88
0.70
46
IP
TC
SHC
IP
0.97
2.74
2.30
1.05
0.99
3.01
2.43
1.07
1.01
3.28
2.53
1.08