CMOS
Message Displayed
CMOS Date/Time Not
Set
CMOS Battery Low
CMOS Settings Wrong
CMOS Checksum Bad
Miscellaneous
Message Displayed
KBC BAT Test failed
Keyboard Error
PS/2 Keyboard not
found
PS/2 Mouse not found
Keyboard/Interface
Error
Unlock Keyboard
System Halted
<INS> Pressed
Password check failed
Unknown BIOS error.
Error code = 004Ah
Unknown BIOS error.
Error code = 004Bh
Floppy Controller
Failure
88
Description
The CMOS date and/or time are invalid. This error can be resolved by readjusting
the system time in AMIBIOS Setup.
CMOS battery is low. This message usually indicates that the CMOS battery
needs to be replaced. It could also appear when the user intentionally discharges
the CMOS battery.
CMOS settings are invalid. This error can be resolved by using AMIBIOS Setup.
CMOS contents failed the Checksum check. Indicates that the CMOS data has
been changed by a program other than the BIOS or that the CMOS is not
retaining its data due to malfunction. This error can typically be resolved by using
AMIBIOS Setup.
Description
Keyboard controller BAT test failed. This may indicate a problem with keyboard
controller initialization.
Keyboard is not present or the hardware is not responding when the keyboard
controller is initialized.
PS/2 keyboard support is enabled in the BIOS setup but the device is not
detected.
PS/2 mouse support is enabled in the BIOS setup but the device is not detected.
Keyboard controller failure. This may indicate a problem with system hardware.
PS/2 keyboard is locked. User needs to unlock the keyboard to continue the
BIOS POST.
The system has been halted. A reset or power cycle is required to reboot the
machine. This message appears after a fatal error has been detected.
Indicates that <INS> key is pressed during the BIOS POST. The POST will load
and use default CMOS settings.
The password entered does not match the password set in the setup. This
condition may occur for both Supervisor and User password verification.
This message is displayed when ADM module is not present in the AMIBIOS8
ROM.
This message is displayed when language module is not present in the
AMIBIOS8 ROM.
Error in initializing legacy Floppy Controller.