Dell 5310n - Workgroup Laser Printer B/W Service Manual page 123

Service manual
Table of Contents

Advertisement

FRU
+5 V dc test point on the
3
system board
System board
4
LVPS
5
Features or option installed
6
on the interconnect card
assembly
LVPS fuse F1 (primary
7
power)
Loads connected to the
8
system board
Action
Check for approximately +5 V dc at the +5 V test point on the system
board.
Note: Use care not to short adjacent voltage test points.
If the voltage is correct, replace the system board assembly. If the
voltage is incorrect, go to step 4.
Check to make sure the LVPS cable is correctly installed at J27 on
the system board. If not, reseat and recheck the voltage at the
+5 V dc test point on the system board.
If test point does not measure +5 V dc, go to step 5.
Unplug the AC line cord from the LVPS and disconnect the LVPS
cable to the system board. Reconnect the AC line cord and measure
the voltage on CN2-1 on the LVPS. The voltage should measure
approximately +5 V dc.
If the voltage is correct, go to step 6. If the voltage is incorrect,
replace the LVPS assembly. See
removal" on page 4-55
Warning: Observe all the ESD precautions and turn the printer off
before any feature or option cards are removed or replaced.
Remove one option/feature at a time to help isolate the failing part.
Replace the faulty part.
Unplug the AC line cord, remove the LVPS from the printer, and
check the continuity of fuse F1. See
removal" on page
4-55.
If continuity is correct, replace the LVPS assembly.
If the voltage is incorrect, replace the LVPS assembly.
Turn the printer off and disconnect each cable connected to the
system board and each option installed on the system board until the
problem is located.
Warning: When removing any card installed on the system board
observe all ESD precautions when handling these options.
"Low voltage power supply
"Low voltage power supply
Diagnostic information
2-81

Advertisement

Table of Contents
loading

This manual is also suitable for:

5210n5310n

Table of Contents