Venting Requirements - Whirlpool UXI6536BSS Installation Instructions And Use And Care Manual

36" (91.4 cm) island-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Product Dimensions
A
F
A. 12¼" (31.1 cm)
B. 13
" (33.5 cm)
C. *29 " (75.6 cm) min. 44
**29 " (75.6 cm) min. 49
D. 3 " (8.9 cm)
E. 36" (91.4 cm)
F. 25
" (64.0 cm)
*Vented installations only
**Non-vented (recirculating) installations only
Installation Dimensions
B
A
A. Countertop height
B. Hood height from ceiling to bottom of the range
hood filter surface: D-A-C=B
C. Hood height: 24" (61.0 cm) min. from electric
cooking surface, 27" (68.6 cm) min. from gas
cooking surface, suggested 36" (91.4 cm) max.
D. Ceiling height
IMPORTANT:
Minimum distance "C": 24" (61.0 cm) from electric cooking
surface, 27" (68.6 cm) from gas cooking surface
Suggested maximum distance "C": 36" (91.4 cm)
6
B
C
D
E
" (113.8 cm) max.
" (126.5 cm) max.
D
C
The chimneys can be adjusted for different ceiling heights. See
the following chart.
Vented Installations
Min. ceiling height
Electric cooking
7' " (2.34 m)
surface
Gas cooking
7'11" (2.41 m)
surface
Non-vented (recirculating) Installations
Min. ceiling height
Electric cooking
7' " (2.34 m)
surface
Gas cooking
7'11" (2.41 m)
surface
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance "C" between the bottom of the range hood and the
cooking surface. For higher ceilings, a Stainless Steel Chimney
Extension Kit Part Number W10272078 is available from your
dealer or an authorized parts distributor. The chimney extension
replaces the chimney shipped with the range hood.

Venting Requirements

Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended. Do
not use plastic or metal foil vent.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
For the most efficient and quiet operation:
Use a straight run or as few elbows as possible.
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Max. ceiling height
9'
" (3.0 m)
9'
" (3.0 m)
Max. ceiling height
10' " (3.12 m)
10' " (3.12 m)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uxi6536bs

Table of Contents