1
/
" minimum distance between
2
rear edge of cutout and nearest
vertical combustible surface
25" min.
30" Gas Drop-In Cooktop Specifications
Product Weight – 43 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = .001 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 1.0 Amps
Always consult local and /or national electric and gas codes.
Recommended location for grounded 120V outlet is on rear wall in an
8" wide by 10" high area, positioned 22" above floor surface and 12" to
right side of cooktop centerline. Access to underside of cooktop and
junction box must be provided for inspection and service.
Cooktop ships with 3/4" factory regulator.
Lp conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
250 Bobby Jones Expressway
USA
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
EW30GC55G 01/08
13"
max.
cabinet
depth
4
1
/
"
4
19"
Overall depth at
center of arc – 21
19
1
/
" min.
8
19
3
/
" max.
4
24"
Augusta, GA 30907
1-877 -4electrolux (1-877 -435-3287)
1-800-265-8352
© 2008 Electrolux Major Appliances, NA
30"
20
7
/
"
30"
8
27"
C L
8" min.*
3
/
"
4
Opening to route 48" power
cable & gas supply
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 2-1/2" minimum distance between rear edge of cutout to nearest
combustible surface above countertop.
Allow 9" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
Drawers cannot be installed beneath this cooktop.
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Gas Drop-In Cooktop model EW30GC55G is approved to be used
over any Electrolux Single Wall Oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Simmer Plate – (318254208).
Wok Ring – (318254307).
electroluxappliances.com
electroluxappliances.ca
30" min.
for
unprotected
cabinet
24" min.
for
protected
18"
surface
min.
5
/
"
8
9" min. to nearest
combustible wall
(either side of unit)
27
1
/
" min.
4
28
1
/
" max.
2
* Includes a 5" space beneath
cooktop for connection to
gas supply line
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Printed in the U.S.A.

Advertisement

loading

  Related Manuals for Electrolux EW30GC55GB

This manual is also suitable for:

Ew30gc55g wEw30gc55g sEw30gc55gsEw30gc55g b