4. PREPARATION BEFORE SEWING

4-1. Installing the needle

Turn off the power switch before installing the needle.
Otherwise the machine may operate if the start switch is pressed by mistake, which could result in serious injury.
(seen from the right side)
(Seen from the front)
CAUTION
1. Remove the work clamp plates. (Refer to "3-19. Installing
0393B
and removing the work clamp plates" for details on
removing the plates.)
2. Check that the index mark (1) on the bed is aligned with
the index mark (2) on the looper base.
*
If they are not aligned, turn the looper base (3) until
they are aligned.
3. Raise the finger guard (4).
0394B
4. Loosen the set screw (5), and then remove the needle
(6).
5. Insert the new needle (7) as far as it will go, with the
hollow (A) facing toward the front.
6. Securely tighten the set screw (5).
7. Lower the finger guard (4).
NOTE:
Do not tighten the set screw (5) while the needle has been
removed. If the set screw (5) is tightened, it may damage
the inside of the needle bar and it may not be possible to
insert the needle.
<Recommended needle>
DO x 558 80 - 120 Nm (Schmetz 558)
0395B
RH-9820