Download  Print this page

List Of Error Codes - Brother RH-981A Instruction Manual

Electronic eyelet button holer.
Hide thumbs

Advertisement

12. LIST OF ERROR CODES

12. LIST OF ERROR CODES
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall
outlet before opening the face plate of the control box. Touching areas where high voltages are present can
result in severe injury.
When an error occurs, the warning indicator and the error code display flash and the buzzer sounds.
Code
E-00
EMERGENCY STOP switch was pressed.
E-02
Machine head is tilted back.
E-03
Cloth presser switch was pressed.
E-04
Start switch was pressed.
E-05
Air pressure is insufficient.
E-06
Feed plate home position sensor is OFF.
E-07
Feed plate left range sensor is OFF.
Specification that machine does not support
E-09
is set.
E-10
Needle bar is not at the highest position.
E-12
Cutter sensor is ON.
E-15
Lower thread trimming OFF sensor is OFF.
E-26
PER terminal connection error
E-27
External RAM error
E-28
Panel communication start error
E-29
Machine motor communication start error
77
Errors after power is turned on
Explanation
DANGER
Resetting method
1. Release the EMERGENCY STOP switch.
2. If an error still occurs after 1. is carried out, check that connector
P3 on the control circuit board is properly connected.
1. Turn off the power.
2. Return the machine head to its original position.
3. If an error still occurs after 1. is carried out, check that connector
P8 on the control circuit board is properly connected.
1. Release the cloth presser switch.
2. If an error still occurs after 1. is carried out, check that connector
P19 on the control circuit board is properly connected.
1. Release the start switch.
2. If an error still occurs after 1. is carried out, check that connector
P19 on the control circuit board is properly connected.
1. Turn off the power.
2. Check the air pressure.
3. Check that connector P1 on the control circuit board is properly
connected.
1. Move the cloth feed bar to the left so that the feed plate home
position sensor turns ON.
2. If an error still occurs after 1. is carried out, check that connector
P9 on the control circuit board is properly connected.
Turn off the power and check that connector P9 on the control
circuit board is properly connected.
1. Turn off the power.
2. Check the specification harness and PROM.
3. Check that connector P26 on the control circuit board is properly
connected.
1. Turn the pulley by hand to raise the needle bar to its highest
position.
2. If an error still occurs after 1. is carried out, check that connector
P2 on the control circuit board is properly connected.
Turn off the power and check that connector P3 on the control
circuit board is properly connected.
Turn off the power and check that connector P8 on the control
circuit board is properly connected.
1. Turn off the power.
2. Check that connector P20 on the control circuit board is properly
connected.
3. Check that connector P2 on the power supply circuit board is
properly connected.
Turn off the power.
1. Turn off the power.
2. Check that connector P18 on the control circuit board is properly
connected.
3. Check that connector P1 on the panel circuit board is properly
connected.