10. CHANGING FUNCTIONS USING THE MEMORY SWITCHES
10-1. Memory switch table
The memory switch settings are applied immediately to all programs once the settings have been changed.
However, memory switches marked with * are only applied after the power is turned on.
No.
00.
Cloth presser down operation when feed bracket is
forward
01.
Cloth presser stays down after sewing
02.
Number of home position start cycles (Note 1)
03.
Cutting block ON time
Timer for checking raising of hammer
04.
(Timer for determining if the cutting block has been
raised to a position where it will not touch the next
feed bracket to operate)
Feed operation timing correction after hammer is
05.
raised
(After checking that the hammer is raised, the timer
interval is added so that the hammer and feed
bracket do not touch.)
06.
Test feeding deceleration speed
07.
Increased amount of upper thread remaining
08.
Stitch length display in automatic mode
09.*
Max. stitch length of L7
10.
Feed timing correction
11.*
Number of eyelet buttonholes when fly indexer is
used
12.*
Cloth setting position when fly indexer is used
13.
Program number selected when buttonhole sensor
is ON when using the special lapel cutting device
14.
Program
number
buttonhole hammer regardless of eyelet shape
setting (parameter No. 01) and whether the
buttonhole sensor is ON or OFF (Note 2)
(Note 1) If home position starting is not carried out for each piece of material, there is the danger that the feed
bracket may become overloaded for some reason and come off, which will affect the next piece to be sewn.
Accordingly it is recommended that you set home position starting to be carried out each time (setting "1").
(Note 2) If a program number has been set for memory switch No. 13, it will be ignored if a program number has
been set for memory switch No. 14.
73
Setting items
for
operating
the
Setting range
OFF, ON
OFF, ON
OFF, 1 - 9
25 - 200 ms
OFF (Determined
from number of slit
signals),
200 - 500 ms
0 - 150 ms
OFF, 1 - 4
OFF, 1 - 3
OFF, ON
40 mm, 42 mm
-10 - 10
OFF (Fly indexer is
not used),1 - 9
1: Left setting
position
2: Horizontal setting
position
OFF, 1 - 9
straight
OFF, 1 - 9
RH-981A
Unit
Default
-
OFF
-
OFF
1
1
25 ms
25 ms
50 ms
OFF
25 ms
0
1
OFF
1
OFF
-
OFF
2 mm
40 mm
1
0
1
1
1
1
1
OFF
1
OFF