Closed defect summary
Invalid Tx/Rx rate can be computed if a polling cycle takes place when
a domain name has not been assigned.
An EZ Switch Manager validation error occurs on existing zones due
to devices of type initiator+target or unknown being treated like stor-
age.
The Accept CT_IU to GA_NXT Request frame is being rejected by a
third-party storage device because the frame size is 680 bytes.
HP 8/80 FRU faulty status not recovered after connecting to correct
power supply after operating with a single power supply.
A Tape Selective Reset error occurs due to incorrect handling of Early
End Synchronization status.
A FICON Device Level Ack Emulation Processing error occurred.
Fabric OS 6.1.1a fixes
Table 10
lists defects closed in the Fabric OS 6.1.1a firmware release.
Table 10 Fabric OS 6.1.1a closed defects
Closed defect summary
The tag field of the node identifier command returned, contains the
port number on which the command was received, instead of the tag
field of the device on the other end of the link.
After systemverification —short is completed on the HP 8/80
SAN Switch, the route is affected on platforms with BI ports.
Third-party application paths fail with FC Fast Write enabled with bid-
irectional traffic due to out of order or dropped frames.
Speed negotiation fails on some 4-Gb Quad-Rate, long-wave, 4-km
SFPs.
Java is running out of memory in WebTools causing sluggish response.
On a backbone switch with both EX_Ports and VE_Ports, or VEX_Ports,
after hafailover and hareboot, the device on the backbone has
no access to the remote device.
Need better response message from CAL when the setting of SCC
policy fails.
When transient failure occurs at the same time as core blade plug in-
sertion, frames could be dropped in the switch, leading to SCSI timeouts
and errors.
24
Solution
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Solution
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.
Fixed in Fabric OS 6.1.1a.