Chapter 3
1. Use the marking pen to mark the 2nd and 14th holes on both front
columns, as shown on the template. See Figure 3-2.
NOTE
The two column adapters are mounted at the 2nd and 14th
holes on the respective front column and provide the captive
nuts for mounting the rack slides to the front columns at 7th
and 9th holes from the bottom. If you don't have the template,
Figure 3-2 shows the location on the front columns for the
column adapters.
"#" represents
the EIA unit
numbers on the
rack columns.
Bottom of
Compaq
Rack
Figure 3-2. Location Marks on the Rack's Front Columns
2. Mount cage nuts (at 7th and 9th holes) on the left-rear and right-rear rack
columns. See Figure 3-3.
Push In, then Down,
and then Up
Figure 3-3. Placing Cage Nuts on Rack Columns
Figure 3-4 shows cage nut placement for the two rear rack columns.
14
Rack-Mounting the HP NetServer
#
14th Hole
From Bottom
#
#
#
#
2nd Hole
From Bottom
Rack Nut from the Front
Of the Rack Column