HP StorageWorks P9000 Software Installation Manual page 29

Business continuity manager software installation guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

YKLCNSE=[prefix] ~ <8 or fewer alphanumeric characters>
Specify a prefix1 for the license information dataset so that the name of the dataset
is unique. If the prefix1 is omitted, specify PARM='YKLCNSE='.
For details about the prefix1 for the license information dataset, see
Conventions for License Information Datasets" (page
YKLCNS2=[prefix2] ~ <8 or fewer alphanumeric characters>
Specify a prefix2 for the license information dataset so that the name of the dataset
is unique. If the prefix2 is omitted, specify PARM='YKLCNS2='.
For details about the prefix2 for the license information dataset, see
Conventions for License Information Datasets" (page
LOGPUT=[LOGR | SAM]
Specify whether or not the system logger service is to be used, when outputting
Business Continuity Manager logs.
The specified value for the LOGPUT parameter is given priority over the &YKLOGPT
system symbol in the IEASYMxx parmlib member. If this command is executed with
the LOGPUT parameter omitted (PARM='LOGPUT=' is specified), the value of the
&YKLOGPT system symbol will be used.
LOGR: Business Continuity Manager logs are output using the system logger service.
SAM: Business Continuity Manager logs are output to sequential datasets.
SYSLOG=[YES | NO]
Specify whether or not CLI command-execution logs are output to SYSLOG.
The value specified for the SYSLOG parameter is given priority over the &YKSYSLG
system symbol in the IEASYMxx parmlib member. If this command is executed with
the SYSLOG parameter omitted (PARM='SYSLOG=' is specified), the value of the
&YKSYSLG system symbol will be used.
YES: CLI command-execution logs are output to SYSLOG.
NO: CLI command-execution logs are not output to SYSLOG.
For details about commands that collect CLI command-execution logs, see the HP
StorageWorks P9000 for Business Continuity Manager Software User Guide.
NOTE:
The setting made by executing the YKSETENV command (of Business
Continuity Manager earlier than version 5.1) with SYSLOG=YES specified has the
same effect as the setting made by executing the YKSETENV command (of Business
Continuity Manager 5.1 or later) with no SYSLOG parameter specified. Be careful
when multiple versions are used in an environment, or when performing an upgrade.
To determine whether CLI command-execution logs are output to SYSLOG when
multiple versions are used, see
Command-Execution Logs (SYSLOG)" (page
Return Codes
Table 15 YKSETENV Command Return Codes List
Return Code
Meaning
Successful completion.
0
The specified value is incorrect. Another value was used for execution.
4
The specified value is incorrect. Processing was cancelled.
8
44).
44).
"Specifying Whether to Output the CLI
108).
Installing Business Continuity Manager
"Naming
"Naming
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents