Table 65 Error codes (part code 8105) (continued)
Part
Error
Code
Number
8105
1352
8105
1353
8105
1354
8105
1355
8105
1356
8105
1357
8105
1364
8105
1600
8105
1601
8105
1904
8105
1906
8105
1910
8105
191 1
8105
1912
276 Message (part code group 8nnn)
Error Message
Logical paths remain on the Fibre-MCU
port. This operation may cause a fatal
damage to the logical paths. Please stop
this operation. If you want to continue
this operation, please remove the logical
paths from the MCU port first.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to S-VOLs. Please stop this
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
Failed to add the WWN to the initiator
port.
The host mode of the host group
connected to the Initiator port cannot be
changed.
The host group cannot be added to the
Initiator port.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to the S-VOLs. Please stop this
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
The port type is incorrect.
This functionality is not available. Open
System Array Management is required.
This functionality is not available. Open
System Array Management is required.
The specified volume cannot be assigned
as an LUSE volume or a command
device, and the path of the volume
cannot be set because it is being used
as a Pool volume.
The specified volume cannot be set as a
command device because it is being
used as a V-VOL for Snapshot.
The specified volume contains Snapshot
pairs.
The specified volume contains Pool-VOLs.
The specified volume is a remote
command device, and therefore the
command device setting or the command
device security setting cannot be set or
released.
Recommended Action
Since the port you are trying to set is for
Remote Copy, you must delete the logical
path, then retry the port setting.
Since the port you are trying to set is for
Remote Copy, you must delete the S-VOL
logical path that is set to RCU Target,
then retry the port setting.
The port you are trying to set is for
Remote Copy. You must change the
attribute (Target or RCU Target) when
adding a WWN.
The port you are trying to set is for
Remote Copy. You must change the
attribute (Target or RCU Target) when
adding a WWN.
The port you are trying to set is for
Remote Copy. You must change the
attribute (Target or RCU Target) when
adding a host group.
The specified Port is for Fibre Continuous
Access Synchronous. Delete a logical
path, then retry the operation.
Check the port type, then retry the
operation.
Install the necessary program product
licence key.
Install the necessary program product
licence key.
Select another volume.
Select another volume.
Select another volume.
Select another volume.
Correct the settings, then retry the
operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W