Table 59 Error codes (part code 7005) (continued)
Part
Error
Error Message
Code
Number
7005
58482
The operation cannot be performed,
because the specified reserved volume
is a P-VOL for Snapshot.
7005
58483
The operation cannot be performed,
because the specified reserved volume
is a V-VOL for Snapshot.
7005
58484
The operation cannot be performed,
because the specified reserved volume
is a pool volume.
7005
58492
The Pairsplit-S operation has failed.
Check the configuration.
7005
58493
The PCB required for this operation is
not mounted. Check the subsystem
configuration.
7005
58520
The operation failed, because different
versions of microcodes coexisted in the
disk subsystem.
7005
58533
The operation failed, because the
specified P-VOL was a journal volume.
7005
58534
The operation failed, because the
specified S-VOL was a journal volume.
7005
58535
The reserve volume setting failed
because the specified volume was a
journal volume.
7005
58536
The operation failed because the
specified S-VOL was a data volume of
Continuous Access Journal. Check the
requirements for using the volume with
Continuous Access Journal.
7005
58572
An error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
7005
58573
This function is not supported.
7005
58574
An error occurred while connecting to
the subsystem.
7005
58575
An error occurred while connecting to
the subsystem.
7005
58576
A communication time-out error occurred
on the storage system.
7005
58579
The operation failed, because the
specified volume is being shredded by
Data Retention. Retry the operation after
the shredding is completed.
Recommended Action
Release the Snapshot pair, or select
another volume.
Specify another volume.
Release the pool volume, or select
another volume.
Refresh the window, and check whether
the pair exists.
Mount the required PCB, then retry the
operation.
Replace the microcode, then retry the
operation.
Release the journal volume setting, or
specify another volume.
Release the journal volume setting, or
specify another volume.
Release the journal volume setting, or
specify another volume.
Check the requirements for using the
volume with Continuous Access Journal.
An error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
Check if the DKCMAIN and SVP
microcode versions are mismatched.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
Severity
Level
W
W
W
W
E
E
W
W
W
W
E
E
E
E
E
W
Part code 7005 245